00196457-05_UM_SX12DX12_SR706_EN.pdf - 第326页

6 Station extensions User manual SIPLACE SX1/SX2/DX1/DX2 6.1 Nozzle changer From software version SC.706.xx Version 06/2012 EN 326 6.1.4.2 T echnical dat a 6 6.1.4.3 Position of the nozzle changers for t he 12 segment C&…

100%1 / 380
User manual SIPLACE SX1/SX2/DX1/DX2 6 Station extensions
From software version SC.706.xx Version 06/2012 EN 6.1 Nozzle changer
325
6.1.4 Nozzle changer for the 12 segment Collect&Place head
Item no. 00120604-xx Nozzle changer DX, C&P12 for position 1 or 2
6
Fig. 6.1 - 17 Nozzle changer for the SIPLACE SpeedStar
6.1.4.1 Description
This nozzle changer can accommodate 4 magazines, each with 12 nozzle garages.
The magazines are seated on a common support. They are centered with two parallel pins and
fixed in place with 4 push buttons. The exact position is determined with two fiducials on each
magazine. The correct seat of the magazines on the basic nozzle changer body is monitored by
microswitches, to prevent a collision of the placement head with any magazines projecting up-
wards. All magazine locations must be filled since the safety circuit stops the machine in response
to missing magazines or magazines that are not seated correctly.
At the installed nozzle station, components can be blown off the nozzles of the SpeedStar and noz-
zles stripped off and rejected.
CAUTION
The magazine for the 12 segment C&P head may only be used together with the 12 segment C&P
head. 6
6 Station extensions User manual SIPLACE SX1/SX2/DX1/DX2
6.1 Nozzle changer From software version SC.706.xx Version 06/2012 EN
326
6.1.4.2 Technical data
6
6.1.4.3 Position of the nozzle changers for the 12 segment C&P head in DX machines
6
Fig. 6.1 - 18 Position of nozzle changer for the SIPLACE SpeedStar - example of DX2
6
Nozzle changer for the SIPLACE 12 segment C&P head
Dimensions (length x width x height) 314 mm x 94.5 mm x 68.6 mm
Number of nozzle holders 48
Number of nozzle magazines 4
Nozzle types 3xxx
Nozzle changeover time approx. 2s per nozzle
Compressed air connection 0.45 MPa (4.5 bar)
(1) DX tables (PA) Placement area
(PPW) Nozzle changer
(1)
(1)
User manual SIPLACE SX1/SX2/DX1/DX2 6 Station extensions
From software version SC.706.xx Version 06/2012 EN 6.1 Nozzle changer
327
6.1.4.4 Assembly
In DX1/DX2 machines, the nozzle changers are fixed to the DX table.
6
Fig. 6.1 - 19 Assembly position
(1) Sloping side points towards the DX table
(2) Vertical side points towards the PCB conveyor
Align the nozzle changer so that the sloping side points towards the DX table.
WARNING 6
Only install the associated nozzle changer for each placement head, with the nozzle maga-
zines for the respective placement head. There is a risk of head crashes with mixed configu-
rations.