2.1.3.2 Safety of operators and other persons
Machine operators must only carry out work for which they have been adequately trained and
with which they are totally familiar.
NEVER open one of the protective covers if you are not totally familiar with the use and func-
tioning of the machine! Do not open the protective covers during operation unless you are told
to do so in this manual or in the station software dialog.
NEVER place your head or arms in the gantry and lifting table traveling range while the station
is switched on!
For your own safety, wear work clothes that conform to the guidelines of the professional as-
sociation, i.e. no wide sleeves etc.
Reduce the risks by not wearing scarves, chains or ties at your work post.
People with long hair must wear a protective head covering.
WARNING 2
The system is electrically driven. When electrical devices are in use, certain parts carry dangerous
voltage levels.
Switch off at the main switch and disconnect the placement machine from the power supply
before carrying out any work on live components.
Lock the machine as described in section 2.11, page 89.
There is a risk of death, severe injury and/or considerable damage to equipment if these instruc-
tions are not followed.
2.1.3.3 Safety of plant and equipment
Never make changes, however minor, unless you are totally aware of the effect they will have
on the overall functioning of the system.
The stations must always be set up, retooled and maintained by appropriately trained person-
nel.
Do not make modifications to the safety equipment. In particular, NEVER deactivate circuit-
breakers or remove safety devices.
2 Operational safety User Manual SIPLACE SX1/SX2/DX1/DX2
2.1 Safety instructions From software version SC.706.xx Version 06/2012 EN
38
2.1.4 Safety instructions for laser units
Permission to operate components that are classified as lasers is withdrawn if
mechanical damage to the unit is observed, or
any work is done on the mechanical or electrical parts of the unit. Even damaged or miss-
ing screw locking paint on laser components (e.g. cover plates, fasteners, adjusting po-
tentiometer) counts as work.
Only ASM Assembly Systems GmbH&Co.KG service engineers or the machine owner's
service engineers, who have been trained by ASM, may replace laser components.
Repairs to laser units are carried out at the ASM factory exclusively.
2.1.5 Safety instructions on permanent magnets
Powerful permanent magnets are used for the linear motors of the X and Y axes.
DANGER OF DEATH
POWERFUL PERMANENT MAGNETIC FIELDS INSIDE THE MACHINE 2
The life of persons with passive or active implants such as pacemakers, defibrillators, insulin
pumps etc. is put at risk inside the machine if protective covers are opened.
At-risk people must not stand in the immediate vicinity of the machine.
WARNING
DANGER OF CRUSHING 2
There is a danger of crushing for persons with passive metal implants (e.g. plates, screws).
Never reach into the machine when the protective covers are open and do not bend over the
open machine.
Do not bring any metal objects into the danger area.
User Manual SIPLACE SX1/SX2/DX1/DX2 2 Operational safety
From software version SC.706.xx Version 06/2012 EN 2.1 Safety instructions
39
CAUTION
POWERFUL PERMANENT MAGNETIC FIELDS 2
There is a risk that the powerful magnetic fields could corrupt data on data media or credit cards
and check cards.
Fig. 2.1 - 1 Position of the permanent magnets for the linear drives (example of SX2)
(1) Permanent magnets for X linear motors on gantry 2
(2) Permanent magnets for Y linear motors on gantry 1 and gantry 2 (for loose or fixed bearing)
(3) Permanent magnets for X linear motors on gantry 1
(4) Permanent magnets for Y linear motors on gantry 1 and gantry 2 (for loose or fixed bearing)
(T) Direction of PCB transport
Please note the following points when working on the permanent magnets:
People with active implants (e.g. heart pacemakers) or other ferromagnetic prostheses are
expressly prohibited from working on or coming near these devices. Always keep a safe dis-
tance from the linear motor.