00196457-05_UM_SX12DX12_SR706_EN.pdf - 第251页
User Manual SIPLACE SX1/SX2/DX1/DX2 5 Working with the machine From software version SC.706.xx Version 06/2012 EN 5.3 Switching on the SIPLACE line 251 5.3.5 Action perf ormed by machin e start button The action performe…

5 Working with the machine User Manual SIPLACE SX1/SX2/DX1/DX2
5.3 Switching on the SIPLACE line From software version SC.706.xx Version 06/2012 EN
250
5
Fig. 5.3 - 1 "Production" view after loading the station software (example of SIPLACEX4i shown)
The status field (see section 5.5.1, page 255) shows the current status of the station and the action
to be performed.
Press the start button when you see the request "Press Start button".
Start buttons can be found on the input side, output side and on the operating panels to the
left and right of the station.
A reference run will be performed. After completion of this reference run, the station is ready
for operation.
The icon will be shown in the working area of the user interface (enabled).

User Manual SIPLACE SX1/SX2/DX1/DX2 5 Working with the machine
From software version SC.706.xx Version 06/2012 EN 5.3 Switching on the SIPLACE line
251
5.3.5 Action performed by machine start button
The action performed by the start button can be set.
Open the "Check sensors and functions" view (see section 5.5.3, page 256).
The following settings are possible:
Start production automatically 5
Standard setting.
Pressing the start button automatically begins the production process.
Produktionsstatus nicht ändern 5
This is used, for example, to calibrate and test the machine
Pressing the start button simply closes the electricity circuit; production is not started immediately.
CAUTION
Machine functions can be directly started via the GUI, irrespective of the start button setting. If the
electrical circuit has already been closed, you do not need to confirm with the start button again.5
5.3.6 "Switching on the SIPLACE line" flow chart
The following flow diagram shows the actions performed after the SIPLACE line has been
switched on.

5 Working with the machine User Manual SIPLACE SX1/SX2/DX1/DX2
5.3 Switching on the SIPLACE line From software version SC.706.xx Version 06/2012 EN
252
5
Fig. 5.3 - 2 Flow chart - switching on the "SIPLACE line"
Station computer
Switch on
Check setup
(configure feeder modules
Teach fiducials
Load board data
Press start button
Wait for reference run
Move board in
Wait for PCB
Check setup
(if table marked red
If required: change nozzle configuration
Nozzle check
Fiducials
OK?
Track er-
ror
Placement
Check setup
Fill up tracks
Placement
PCB in output conveyor
Italics: Performed or reported by the station
Yes
Yes
No
No
Presettings at machine
Download assistant
Programming system
Tasks
Confirm conversion in download
assistant
Bold lettering: job to be performed by op-
erator