User Manual SIPLACE SX1/SX2/DX1/DX2 2 Operational safety
From software version SC.706.xx Version 06/2012 EN 2.7 Safety equipment
73
2.7.3 Position of protective contactor combination and service socket
2
Fig. 2.7 - 6 Position of protective contactor combination and service socket
2
(1) Protective contactor combination
(2) Service socket
(2)
(1)
2 Operational safety User Manual SIPLACE SX1/SX2/DX1/DX2
2.7 Safety equipment From software version SC.706.xx Version 06/2012 EN
74
Protective contactor combination K3 ( item 1 in fig. 2.7 - 6, page 73) 2
The protective contactor combination is contained in the power supply unit. It is used to monitor
the EMERGENCY STOP circuits and safety equipment.
There are three conditions that must be fulfilled in order to activate the protective contactor com-
bination:
The "software release" or "Control ON" signal must be issued.
The EMERGENCY STOP loop must be closed.
The start button must have been pressed.
The front side of the protective contactor combination has three green LEDs for the operating dis-
play (see fig. 2.7 - 7
, page 75 )
The "Power" LED indicates that voltage is present.
The "Channel 1" and "Channel 2" LEDs shine if the start button has been pressed, the EMER-
GENCY STOP circuit is closed and the signaling circuit has not indicated any error states.
Service socket ( item 2 in fig. 2.7 - 6, page 73) 2
The service socket is contained in the power supply unit and is protected by the cover. It can only
be used if the machine is connected to the main power supply via a 5-wire connection (L1, L2, L3,
N, and PE). If a 4-wire connection is used, e.g. without N, the socket cannot be used.
WARNING 2
Always follow the safety instructions concerning potentially lethal voltages - even when the
machine is switched off. (see section 2.1.3 from page 36)
User Manual SIPLACE SX1/SX2/DX1/DX2 2 Operational safety
From software version SC.706.xx Version 06/2012 EN 2.7 Safety equipment
75
2.7.4 EMERGENCY STOP loops and signaling circuit
2.7.4.1 Structure of the EMERGENCY STOP loops
The following contacts are connected in series and form the EMERGENCY STOP loop:
Make contact elements for the two protective cover switches
Make contact elements for the two Y axis bumper monitors (SX1/SX2 only)
Normally open (NO) contacts for the two EMERGENCY STOP buttons
Make contact elements for the two component trolleys/DX changeover table
Channels for the protective contactor combination SSK K3
In the EMERGENCY STOP loop, the CAN bus signal from the signaling circuit (see section
2.7.4.2
, page 76) is fed to the protective contactor combination SSK K3. If the EMERGENCY
STOP loop is closed, and the signaling circuit is not signaling a malfunction, then the two green
LEDs for channels 1 and 2 light up, in addition to the green mains power check LED of the pro-
tective contactor combination.
2
Fig. 2.7 - 7 Signal LED on the protective contactor combination
(1) Mains / Power
(2) Kanal 1 / Channel 1
(3) Kanal 2 / Channel 2
(1)
(2)
(3)