00196457-05_UM_SX12DX12_SR706_EN.pdf - 第269页
User Manual SIPLACE SX1/SX2/DX1/DX2 5 Working with the machine From software version SC.706.xx V ersion 06/2012 EN 5.7 Indicator lamps 269 5.7.2.2 Frequency of flashes 5 5 5.7.2.3 Priorities 5 5.7.2.4 Reaction time Each …

5 Working with the machine User Manual SIPLACE SX1/SX2/DX1/DX2
5.7 Indicator lamps From software version SC.706.xx Version 06/2012 EN
268
5.7.2.1 Basics
5
The filling level of the pickup
position or dipping module is
low.
Respective side White: 100 -200
Green: Off
Red: Off
Yellow: On
Green: On
Unable to move one of the
boards to the next area.
Respective side White: On
Green: Off
Red: Off
Yellow: 500 - 500
Green: Off
Unable to read the board bar-
code in the input conveyor. The
operator must insert the board
manually.
Respective side Not configured Red: Off
Yellow: 500 - 500
Green: Off
The machine has been auto-
matically stopped due to a non-
configured event e.g. conveyor
error. Events which have not
been configured and which
could lead to a machine stop
have not be taken into consid-
eration here.
Both sides White: On
Green: Off
Red: Off
Yellow: 500 - 500
Green: Off
The production has been auto-
matically stopped (e.g. there is
no component ready for pick-
up).
Respective side White: On
Green: Off
Red: Off
Yellow: 500 - 500
Green: Off
The machine is performing a
manual function triggered by
the operator.
White: 100 -1000
Green: 700 - 700
Red: Off
Yellow: Off
Green: 500 - 500
The machine has been stopped
due to a fiducial measurement
error (e.g. board, table, feeder
module).
Both sides White: On
Green: Off
Red: Off
Yellow: 500 - 500
Green: Off
The safety loop has not closed. Respective side White: On
Green: Off
Red: On
Yellow: Off
Green: Off
Meaning Machine side Status - two color
(white/green)
Status - three color
(red/yellow/green)
Status Meaning
Off No warning and no alert
Flashes Warning, the frequency varies depending on the type of warning
On Alert

User Manual SIPLACE SX1/SX2/DX1/DX2 5 Working with the machine
From software version SC.706.xx Version 06/2012 EN 5.7 Indicator lamps
269
5.7.2.2 Frequency of flashes
5
5
5.7.2.3 Priorities
5
5.7.2.4 Reaction time
Each change to the machine status is shown at the indicator lamps within three seconds.
Normal flashing Green indicator lamp: 700 ms off, 700 ms on
White indicator lamp: 500 ms off, 500 ms on
Short flashing 100 ms off, 1000 ms on
Fast flashing 100 ms off, 200 ms on
Type of warning Priority
Definition for fast flashing Top
Definition for normal flashing Medium
Definition for short flashing Lowest

5 Working with the machine User Manual SIPLACE SX1/SX2/DX1/DX2
5.8 Changing shift From software version SC.706.xx Version 06/2012 EN
270
5.8 Changing shift
5.8.1 Activities at shift change
Splice the tapes early. The feeder modules do not have to be refilled as soon as the new shift
starts. This minimizes extended down times.
At the shift change, pass important information on to the next operator. This includes, for in-
stance, changes to the placement program. Also read through the list of the descriptions of
the steps to take in section 5.12
, page 293.
Carry out a setup check.
Make sure that the feeder modules are equipped with the correct components, that they are
at the correct locations on the component trolley/DX tables/DX changeover tables and that
the conveyor increment is set correctly.
Clean the following line assemblies:
Empty the reject bin and carefully vacuum the area around the reject bin.
Carefully vacuum the nozzle changers, feeder modules and the component trolley/DX tables/
DX changeover tables.
Empty the waste tape container. Follow the safety instructions given in section 5.8.2, page
271
.