00196457-05_UM_SX12DX12_SR706_EN.pdf - 第336页

6 Station extensions User manual SIPLACE SX1/SX2/DX1/DX2 6.2 Waffle pack changer (WPC5/WPC6) From software version SC.706.xx Version 06/2012 EN 336 6.2.7 Dimensions with WPC5/WPC6 6 Fig. 6.2 - 3 Dimensions of SX machine …

100%1 / 380
User manual SIPLACE SX1/SX2/DX1/DX2 6 Station extensions
From software version SC.706.xx Version 06/2012 EN 6.2 Waffle pack changer (WPC5/WPC6)
335
6.2.5.2 Electrical ratings
6
6.2.5.3 Permitted environmental factors
6
6.2.6 Installation notes for WPC5/WPC6
The WPC5/WPC6 can be docked onto the left side (at location 1 or location 2) of the SX/DX ma-
chine.
Supply voltage 3 x 200 V~ ± 5 %; 50/60 Hz (Japan)
3 x 208 V~ ± 5 %; 50/60 Hz (U.S.A)
3 x 230 V~ ± 5 %; 50/60 Hz
3 x 380 V~ ± 5 %; 50/60 Hz
3 x 400 V~ ± 5 %; 50/60 Hz (Europe)
3 x 415 V~ ± 5 %; 50/60 Hz
Nominal apparent power 1.5 kVA
Nominal active power 1.0 kW
Fuse 3 x 10 or 3 x 16 A
Room temperature Between 15°C and 35°C
Atmospheric humidity 30 - 75%
(on average not higher than 45%, so that there is no risk of
condensation on the machine.)
6 Station extensions User manual SIPLACE SX1/SX2/DX1/DX2
6.2 Waffle pack changer (WPC5/WPC6) From software version SC.706.xx Version 06/2012 EN
336
6.2.7 Dimensions with WPC5/WPC6
6
Fig. 6.2 - 3 Dimensions of SX machine with WPC5/WPC6
(1) 3000 mm
(2) 700 mm
(3) 445 mm
(4) 769 mm
(5) Location for component trolley/DX table with 30 tracks
User manual SIPLACE SX1/SX2/DX1/DX2 6 Station extensions
From software version SC.706.xx Version 06/2012 EN 6.2 Waffle pack changer (WPC5/WPC6)
337
6.2.8 Controls
6
Fig. 6.2 - 4 WPC - controls
(1) EMERGENCY STOP button
(2) Main power switch
(3) Crank for raising or lowering the chassis
(4) Safety door
(5) Waffle pack tray storage unit
(6) Non-stop module (WPC6 only)
(3)
(2)
(1)
(4)
(5)
(6)