00196457-05_UM_SX12DX12_SR706_EN.pdf - 第341页
User manual SIPLACE SX1/SX2/DX1/DX2 6 Station exte nsions From software version SC.706.xx Version 06/2012 EN 6. 3 DX changeover tables on the SIPLACE DX1/DX2 341 CAUTION When docking and undockin g, make sure that there …

6 Station extensions User manual SIPLACE SX1/SX2/DX1/DX2
6.3 DX changeover tables on the SIPLACE DX1/DX2 From software version SC.706.xx Version 06/2012 EN
340
PLEASE NOTE:
Feeder modules can be placed on the uneven track numbers. Only these tracks are fitted with an
energy and data interface on the machine, so that the full capacity of 60 8mm tracks can only be
achieved with 30 2x8mm X feeder modules. 6
CAUTION 6
The DX changeover tables may only be docked onto locations at which the DX changeover table
docking unit for the SIPLACE DX1/DX2 has been installed (fig. 5.15 - 4, page 300).
6.3.1 Safety instructions for docking the DX changeover table in or out
WARNING 6
The placement machine may only be operated if there is a DX changeover table present and
docked at each location. Fill any free locations with dummy feeder modules as described in
section 2.7.5.1, page 79.
WARNING
To prevent accidents (risk of crushing), the DX changeover table may only be docked in or out by
one person.
WARNING 6
The waste tape container must be pulled out of the DX changeover table for emptying. There is a
risk of catching your thumbs as you do so. To prevent this, observe the safety instructions in sec-
tion 5.8.2
, page 271.
CAUTION
Do not lift the DX changeover table by its handles (handles could break). 6

User manual SIPLACE SX1/SX2/DX1/DX2 6 Station extensions
From software version SC.706.xx Version 06/2012 EN 6.3 DX changeover tables on the SIPLACE DX1/DX2
341
CAUTION
When docking and undocking, make sure that there are no body limbs in the travel area of the DX
changeover table. 6
6.3.2 Technical data
6
6.3.3 Docking the DX changeover table in or out
The optional DX changeover table is handled in the same way as the component trolley.
See “Docking the component trolley in or out” on page 297.
Component trolley dimensions
Component trolley with
60/2 tracks
(length x width)
Component trolley with
30/2 tracks
(length x width)
760 mm x 864 mm
760 mm x 471 mm
Height with folded-up handles
900 mm (PCB transport height:
930 mm (PCB transport height:
950 mm (PCB transport height:
934 mm
964 mm
984 mm
Weight of component trolley with 60/2 tracks
Without feeder modules
With feeder modules (fully configured)
Weight of component trolley with 30/2 tracks
Without feeder modules
With feeder modules (fully configured)
104 kg
266 kg
76 kg
157 kg
Tape reel diameter
standard
maximum
to 432 mm (17“)
483 mm (19“)
Feeder locations
DX changeover table with 60/2 tracks
DX changeover table with 30/2 tracks
max. 30 feeder modules, each of 2x8 mm X
max. 15 feeder modules, each of 2x8 mm X
Max. component feeding
(Two
DX changeover tables on the SIPLACE
DX1/DX2)
When using a Waffle Pack Changer:
60 feeder modules, each with 2x8 mm X
45 feeder modules, each with 2x8 mm X
Component trolley changeover time < 1 minute
6 Station extensions User manual SIPLACE SX1/SX2/DX1/DX2
6.3 DX changeover tables on the SIPLACE DX1/DX2 From software version SC.706.xx Version 06/2012 EN
342
6.3.4 Adjusting the DX changeover table to the PCB conveyor height
The optional DX changeover table is handled in the same way as the component trolley.
See “Adjusting the component trolley to the PCB conveyor height” on page 236.
6.3.5 Setting up the feeder modules
The optional DX changeover table is handled in the same way as the component trolley.
See “Setting up the feeder modules” on page 277.