CP45-英文版培训教材.pdf - 第108页
ٛ Optimizer Setup Optimizer CP-45/55 Operation Process

Operating Manual Reference Figure
CP-45/55 Operation Process
For TR, Lead Length and
Lead Foot are identical or
different, however, for IC,
Length is larger than Foot at
all times. Input the data with
Lead Foot length smaller than
Lead Length.
(e.g.) If Lead Length = 2.0,
input Lead Foot Length = 0.7 ~ 0.9.
* Algorithm :
IC Part Test Mode of Vision
System is divided into 4 types
as follows:
^
Black Body
:UsedwhenBody
color is black.
^
All Body
: Used when Body
color is white system.
^
OddwithnoLead
: Outline
acknowledge of part without
Lead.
^
OddwithLead
: Connector
outline acknowledge of large
Lead Pitch. This function is to
be used when it is difficult to
set the illumination of Fly
Camera
(e.g.) :Odd with Lead is to be used for
IC Socket of brown system. Place
accuracy is
0.3
o

ٛ Optimizer Setup
Optimizer
CP-45/55 Operation Process

Operating Manual Reference Figure
CP-45/55 Operation Process
* OPTIMIZER
Optimizer executes the programming
function automatically to maximize the
production efficiency by optimizing
the array position and work process
of Tape Feeder, Nozzle, ANC, etc.
Methods to achieve the maximum
production efficiency are shown as
follows:
(1) Minimization of numbers of
nozzle replacement
(2) Maximization of numbers of
concurrent pickup of feeder
(3) Array of Feeder for minimizing
the move time of XY Gantry
(4) Determination of the optimum
placing sequence
The Optimizer executes the
optimized algorithm in
consideration of various work
conditions for achieving the
results above. This chapter
covers the configuring and
setting methods of various
setup screens required for