CP45-英文版培训教材.pdf - 第154页

Large Group Cooling Fan Others Electric Device Small Group Outer Fan PC Fan Filter (Outer Fan) Mouse Keyboard Lamp Teaching Box Monitor Isolation Switch Current Breaker Current Protect Emergenc y Switch Door Switch Relay…

100%1 / 208
Large
Group
PCB Feeder Feeder Station Feeder Upward Vision Air Pressure
Small
Group
Belt
PCB
Sensor
Stopper
End
Hole
Fixer Pin
Upper
Side
Fixed Slot
Refer to
manual of
individual
part
feeder.
Vision
Window
Focus
Set
Pressure
Filter
&Drainer
Overall
Piping
Speed
Control
Contents
to be
checked
Tension,
Coating
Condition,
Wear
window
Contamina
tion
Wear
Edge
Wear,
Vibrated
Part &
Contamin
ation
Wear
Contamina
tion
Set
Condition
s
Set
Conditio
ns
Contamina
tion &
Operation
Air
Leakage
Operating
Speed of
Individual
Part
Inspection Interval
Monthly(M) Daily(D) Monthly(M)
Weekly
(W)
Monthly
(M)
Monthly(M)
Reference
1.2.3.1 1.2.3.6 1.2.3.8 1.2.4.1 1.2.5 1.2.6.1 1.2.6.2 1.2.6.4
Remarks
Contact
C/S when
abnormal
condition
occurs.
Clean out
when
contamina
ted.
Contact C/S
when worn.
Re-set
when
abnorma
l
conditio
ns occur.
Replace
when
contamina
ted.
Contact
C/S when
leaked.
Adjust the
air pressure
by turning
the speed
contoCW
or CCW.
Check
Point
Large
Group
Cooling Fan Others Electric Device
Small
Group
Outer
Fan
PC Fan
Filter
(Outer
Fan)
Mouse Keyboard Lamp
Teaching
Box
Monitor
Isolation
Switch
Current
Breaker
Current
Protect
Emergency
Switch
Door
Switch
Relay Fuse
Content
stobe
checked
Operatin
g
condition,
Noise
Operatin
g
condition,
Noise
Contam
ination,
Clogge
d
Operating Condition
Monitor
Condition
(Discolore
d,
Obscure,T
wisted)
Operating Condition, Worn Condition
Inspection
Interval
Weekly(W) Monthly(M) Monthly(M) Weekly(W) Monthly(M)
Reference
Remarks
Contact C/S when
abnormal conditions occur.
Contact C/S when operating
conditions are improper.
Contact
C/S when
abnormal
conditions
occur.
Contact C/S when abnormal conditions occur.
Check
Point
Table 11. Daily Inspection List
1.1.1.2 Aged and Worn Part Replacement
Large
Group
Head & ANC
PCB
Feeder
Air Pressure
Cooling
FAN
Small
Group
Compliance V-Ring Filter Nozzle Belt
Filter &
Drainer
Filter
(Outer Fan)
Content
to be
checke
d
Check
together
daily
inspection
Check together
daily
inspection
Check
together daily
inspection
Check together
daily
inspection
Check
together daily
inspection
Check
together daily
inspection
Inspection
Interval
Weekly(W) Monthly(M) Daily(D) Monthly(M) Monthly(M) Weekly(W)
Replacement
Interval
Every 3
years
Every 3 years
Every 6
months
Every 2 years Every 3 years Every 1 year
Every 6
months
Remarks
Contact C/S
when
replacing the
part.
Contact C/S
when
replacing the
part.
Contact C/S
when replacing
the part.
Contact C/S
when
replacing the
part.
Contact C/S
when
replacing the
part.
Contact C/S
when
replacing the
part.
Contact C/S
when
replacing the
part.
Check
Point
-> Memo
Part Inspection &
Replacement Interval Setting
This shall be applied in
accordance with the specified
operating environment
conditions.
If the operating conditions are
deteriorated, the interval of part
inspection and replacement can
be reduced.
Table 12. Replacement Interval List