Operating Manual Reference Figure CP-45/55 Operation Process <FLY CAMERA> <FLY CAMERA> * Ball type

100%1 / 208
Operating Manual Reference Figure
CP-45/55 Operation Process
<FIX CAMERA>
<FLY CAMERA>
* 3. FIX - FLY Illumination
Relationship
* Body / Lead type
Note) When using with Fly after Auto
TeachingwithFix,modificationas
above is required.
Operating Manual Reference Figure
CP-45/55 Operation Process
<FLY CAMERA>
<FLY CAMERA>
* Ball type
Operating Manual Reference Figure
CP-45/55 Operation Process
<Rectangular
Part>
<Part Outline
Acknowledge>
<Part Center
Searching>
Lead Width
<Lead Edge Test>
<Part Center
Searching>
<Lead Width>
<Lead Foot Edge
Acknowledge>
<Part Center
Searching>
1) CHIP-Rec' Algorithm
*ChipResistor
< Part Outline Acknowledge >
Measure tangent line of all
directions and calculate the center.
(Used for part of white system)
Acknowledge distance and degree
of tangent line by finding out the
line from the top and the bottom.
* CHIP-Capacitor / MELF
< Lead Foot Edge Acknowledge >
Measure the Size of tangent
lines of the left and the right,
calculate the center, search that
as much as Lead W value and
find out distance and degree of the
tangent lines.
Lead Foot acknowledge type does
not test the part Body.