CP45-英文版培训教材.pdf - 第55页
Operating Manual MODEL Reference Figure CP-45/55 Operation Process ^<Camera> Column To select Camera to test Fiducial Mark. At present this is fixed in "Move Camera". V <6. Form Data> Area To input …

Operating Manual
MODEL
Reference Figure
CP-45/55 Operation Process
a b
dc
fe
V
<5. Mark List> Area
This means Fiducial Mark Type
Data list. This is used for giving
name of Mark and selecting a type.
Select a Circle in here.
^<No> Column: Serial Number for
Fiducial Mark type.
^<Name> Column: Name of Fiducial
Mark.(Max. 10 letters)
6<Shape> Column: To select the
Fiducial Mark type. Selectable Types
are as follows:
a - Circle: Circle type Fiducial
Mark
b - Diamond: Diamond type
Fiducial Mark
c - Rectangle: Rectangle type
Fiducial Mark
d - Rectangle2: Fiducial Mark type
overlapped with two rectangles
e - Triangle: Triangle type Fiducial
Mark
f - Cross: Cross type Fiducial
Mark

Operating Manual
MODEL
Reference Figure
CP-45/55 Operation Process
^<Camera> Column
To select Camera to test Fiducial
Mark. At present this is fixed in
"Move Camera".
V
<6. Form Data> Area
To input Data related with Fiducial
Mark types.
Check it with <Outline> button
and adjust it to the real size.
^<Size X> Edit Box
To set the size of X direction of
Fiducial Mark.(Based on a device
coordinator indicator)
^<Size Y> Edit Box
To set the size of Y direction of
Fiducial Mark.(Based on a device
coordinator indicator)
^<Arm> Edit Box
To set the width of a bar in
Cross type Fiducial Mark.
^<Polarity> Combo Box
To select a color of Fiducial Mark.
Selectable colors are as follows:

Operating Manual
MODEL
Reference Figure
CP-45/55 Operation Process
# White: Use this for ensuring that
Mark is shown lighter than
background.
# Black: Use this for ensuring that
Mark is shown darker than
background.
^<Thickness> Edit Box
To set the thickness of Fiducial
Mark.
0 means the Fiducial Mark of full
size.
Digits except 0 mean that outline
has the thickness as much as the
digit.
^<Rotation> Combo Box
To set the rotation degree of
Fiducial Mark. For a triangle, the
registered data has type with its
edge upwards but the edge faces
the side in the actual direction of
Mark. For these cases, it can be
used for setting the rotation degree.
Set the degree based upon CW.
Selectable degrees are shown as
follows:
# 0: Means that degree of Mark is
0.
# 90: Means that Mark is rotated
with the degree of 90.
# 180: Means that Mark is rotated
with the degree of 180.
# 270: Means that Mark is rotated
with the degree of 270.