CP45-英文版培训教材.pdf - 第182页
Operating Manual Reference Figure CP-45/55 Operation Process 1.2.7 Air Pressure 1.2.7.1 Set Pressure *Check Points* @Check that the supply pressure is suitable to the set pressure (4.5 ~ 5.5 bar). Pressure Gauge Regulato…

Operating Manual Reference Figure
CP-45/55 Operation Process
1.2.6 Upward Vision
1.2.6.1 Cover Glass
*Check Points*
@Check that dust particles, foreign
materials, etc., are adhered to both
sides of Cover Glass
*Actions to be taken*
@Loosen 4 screws at both sides of
LED assembly to disconnect it.
@Clean out both sides of Cover Glass
with soft cloth.
@Assemble the part in the reverse
order.
LED
Cover
Glass
Camera
Fig. 118.Upward Vision
Caution
Cover Glass is easy to break since its material is
glass. Care is to be taken for prohibiting from that.
1.2.6.2 Camera Lens
*Actions to be taken*
@Loosen 4 screws at both sides of
LED assembly to disconnect it.
@Clean out the camera Lens with
soft cloth.
@Assemble the part in the reverse
order.
*Check Points*
@Check that dust particles, foreign
materials, etc. are adhered to the
Camera Lens.

Operating Manual Reference Figure
CP-45/55 Operation Process
1.2.7 Air Pressure
1.2.7.1 Set Pressure
*Check Points*
@Check that the supply pressure is
suitable to the set pressure (4.5 ~
5.5 bar).
Pressure
Gauge
Regulator
Air Filter & Auto
Drainer
Pressure Gauge &
Auto Switch
Fig. 1-19. Pressure Check
*Actions to be taken*
@Adjust the pressure by turning a
handle of the Regulator right and
left.
Caution
Abnormal set pressure may cause some problems to
the system performance. Adjust the set pressure
accurately.

Operating Manual Reference Figure
CP-45/55 Operation Process
1.2.7.2 Air Filter & Auto Drainer
*Check Points*
@Check that moisture is collected in
the Air Filter.
@Check that Filter Element is clogged.
@Check that Filter Element is
decolored.
@Check that moisture in a Drainer
can be drained properly.
@If the tube was failed to fix to the
drainer, fix it to the drainer.
Warning
Failing to disconnect the air pressure when replacing
the air filter may cause serious injury to personnel.
Be sure to disconnect the air pressure.
*Actions to be taken*
@Disconnect the air filter container
by pushing down the lock button
and turning it to the side.
@Disconnect the damaged filter
element.
@Install the new filter element in
the reverse order.
@Assemble the container.