Student Guide SIPLACE X
Edition 09/2005 3 Communication and Control
49
Fig. 3.5 - 5 1 Wire RS232 interface (03041578-01)
Fig. 3.5 - 6 1 Wire CAT 5 Splitter (03040219-01)
(1) CAN Bus Interface to I/O module (2) RS 232 Interface
(3) CAN Bus interface to the machine (4) Switch to recognize the version of the I/O mo-
dule Version 02/03
(5) Switch MA / PC switch to MA (machine) (6) Connector CAT5 cable
LED 1 nozzle changer gantry 1/3 LED 2 Temperatur sensor
LED 3 nozzle changer gantry 4/2 LED 4 Green "OK"
LED 5 Green "Fail"
4
1
2
3
1
5
6
2
Input CAT 5 cable
from RS 232 Interface
Input 24 V for
NC
Output CAT 5
to the NC HUB
Gantry 3or 4
Output CAT 5 to
the 1 Wire gan-
try board
Output CAT 5
to the NC HUB
Gantry 1or 2
1 - 50
Student Guide SIPLACE X
3 Communication and Control Edition 09/2005
50
Fig. 3.5 - 7 1 Wire trailing interface board (03042214-01)
Fig. 3.5 - 8 1 wire hub for NC (03041473-02)
Note:
In future we don‘t have the switch for the location code (only HF). The location code for the
nozzlechanger will be realized via hardware, directly in the connector on the location (X112 / X122
/ X132 / X142) at HF and Siplace X. 3
(1) Input CAT 5 cable from the CAT 5
splitter
(2) SUB-D connector for option (query reject con-
tainer)
(3) Connection NC 1 (4) Connection NC 2
on the right side display (2 LED‘s) for NC C&P6/12 Light barrier NC open/closed and Valve NC
open/closed for each row
on the left side two LED‘s directly on the connector
yellow LED: Reject box components connected
green LED: Reject box nozzles connected
3
Switch: position below Gantry 1/2
position above Gantry 3/4
This board is located directly on the CAN
bus connector of the trailing interface.
Connector CAT5 cable from the 1 wire
distributor
Connection to the second Gantry in the
placement area
4
1
2
3
4
1 - 51
Student Guide SIPLACE X
Edition 09/2005 3 Communication and Control
51
Fig. 3.5 - 9 NC control board only at the 20 C&P head nozzle changer
Fig. 3.5 - 10
Position of temperature sensors on the head plate
Fig. 3.5 - 11 Temperature sensors / gantry recognition
Hinweis:
The temperatursensor are connected directly on the connector X20 or X21 on the Head interface
C500. You can use one of the two connectors. 3
Display (2 LED‘s) for NC C&P20 (The LED‘s are invisible because there is a cover under the NC)
Light barrier NC open/closed and Valve NC open/closed
5. Temperature sensor on the PCB cam-
era
(6) Temperature sensor/ EEPROM gantry recog-
nition
7. Temperature sensor on the PCB cam-
era
(8) Temperature sensor/ EEPROM gantry recog-
nition
5
Connection to 1 wire
hub for NC
1
2
6
6
21