SiplaceX4_en.pdf - 第151页

1 - 5 S tudent Guide SIPLACE X Edition 09/2005 4 Servic es to the machine 5 4.2.1 Naming Convention of Connectors and Cables The wiring on the Siplace X is highly structured. Every cable, connector , di stributo r uses a…

100%1 / 670
1 - 4
Student Guide SIPLACE X
4 Services to the machine Edition 09/2005
4
4.2 Overview power supply
Fig. 4.2 - 1 main power supply unit identical in original - and ’A’ version of the HF-Machine
Legend
(1) DC/DC Converter 24 V (4) Fuse F5 (10A) for star axis
(2) DC/DC Converter 5 V and additional 24V (5) Fuse F11(1A) for inrush current limiter
(3) Safety combination relay K6 (SSK) (6) Unloading thrush L20
1
2
3
4
5
main distributor main
power supply
Inrush current limiter:
a: transformer: EST
b: servo: Ess
transformer T
2
transformer T1
T1
T2
Fuse F61 - fuse F142
6
1 - 5
Student Guide SIPLACE X
Edition 09/2005 4 Services to the machine
5
4.2.1 Naming Convention of Connectors and Cables
The wiring on the Siplace X is highly structured. Every cable, connector, distributor uses an exact
term, which is dedicated to the sections and units in question.The name convention and the
systemacy is explained at the original Siplace X type; this is basically valid for all the Siplace X
machines:
Section 2: term q+ 4
Main-distributor section 2: term X1qa, X2qa, X3qa, ...
CAN I/O module (A1): term X1
qb, X2qb, X3qb, ...
Vision DC/DC converter (A3): term X1
qc, X2qc, X3qc, ...
Vision control unit (A4): term X1
qd, X2qd, X3qd, ...
Circuit board 8-fold AND operation (A5): term X1
qe, X2qe and X3qe
Section 4: term r+ 4
Sub-distributor section 4: term X1ra, X2ra, X3ra, ...
CAN I/O module (A1): term X1
rb, X2rb, X3rb, ...
Vision DC/DC converter (A3): term X1
rc, X2rc, X3rc, ...
Vision control unit (A4): term X1
rc, X2rd, X3rd, ...
Circuit board 8-fold AND operation (A5): term X1
re, X2re and X3re
Handing over constituent (A2): term X30
ra and X31ra
Placement head gantry 1: term a+ 4
Gantry distributor: 00 353593 aa
Gantry interface: 00 363330
ab
Head interface: 03000900
ac
Vision board: 03 321469
au
Placement head gantry 3: term b+(up to Machine MA.No. xx / from MA .No. xx is the term c+) 4
Gantry distributor: 00 353593 ba
Gantry interface: 00 363330
bb
Head interface: 03000900
bc
Vision board: 03 321469
bu
Placement head gantry 4: term d+ 4
Gantry distributor: 00 353593 da ; Head interface: 03000900 dc
Gantry interface: 00 363330
db ; Vision board: 03 321469 du ; Computer unit: X1p+
1 - 6
Student Guide SIPLACE X
4 Services to the machine Edition 09/2005
6
4.2.2 Main distribution Unit, section 2
Fig. 4.2 - 2 section 2, main distributor
Legend:
1. Terminal block X1qa (GND, +3.3V, +5V, +15V, -15V, +24V, +52V, various signals)
2. DC/DC converter for Twin head stationary cameras and PCB camera placement area 2 (A3)
3. Vision illumination control board for Twin head stationary cameras (A4)
4. CAN bus I/O module (SLIO) (A1)
5. Connector bar (connector X2qa - X6qa, X71qa - X74qa and X9qa - X24qa)
6. 8-fold AND operation for safety loop (A5)
52
3
1
4
6