SiplaceX4_en.pdf - 第420页
1 - 54 S tudent Guide SIPLACE X 8 Collect&Place-Head 20 Edition 09/2005 54 8.5.4 Control unit for nozzle changer of the C&P heads The nozzle changer are con trolled depend on the configuration of the loca tion at…

1 - 53
Student Guide SIPLACE X
Edition 09/2005 8 Collect&Place-Head 20
53
8.5.2.1 Nozzle reject unit
For the C&P 20 head reject unit we integreted a part to check and fixed the correct position of the
nozzle to the segment interface.
8.5.3 Adjustment of the height of the nozzle changer C&P 20 head
To get the correct safe distance between head (Component sensor) and nozzle changer is it nec-
essary to measure and adjust the height between mounting surface docking unit and the linear
guide of the X axis.
The distance have to
150,0mm +/-0,2mm. The support of the nozzle changer carrier has to be
adjusted with washers in its height until the the nominal distance is acchieved and then you can
mount the nozzelchangetr.
Fig. 8.5 - 3 Adjusting of nozzle changer at C&P20- head
Please Note for assembling the nozzle changer :
During assembling the nozzle changer keep attention that the component reject box can be easily
removed. Don´t use to long screws, otherwise the component reject box will be fixed.
Nozzle reject unit
Check the nozzle to the segment
interface
Reject nozzles
The height of the nozzle reject
unit have to adjust at
140,0 +\-
0,3 mm. The measurement pro-
cedure is the same like the
nozzle changer (see image be-
low).
Calliper
Top edge of the below linear guide
X-Axis
Mounting surface of the nozzle chan-
ger.
150,0mm +/-0,2

1 - 54
Student Guide SIPLACE X
8 Collect&Place-Head 20 Edition 09/2005
54
8.5.4 Control unit for nozzle changer of the C&P heads
The nozzle changer are controlled depend on the configuration of the location at the machine via
CAN Bus (SLIO Main- und Sub-Distributor). In future with the SW 505 the nozzle changer are con-
trolled via the "One Wire Bus". Soleniods control the pneumatic rotary drives and open or close
the nozzle changer.
Legende
(1) SUB-D connector machine CAN Bus (2) SUB-D connector Option ( reject boxes / 24 V)
(3) ribbon cable nozzle changer 1 (4) ribbon cable nozzle changer 2
Location
code
LED check DLM nozzle
changer 2
1
2
3
4
LED check DLM
nozzlechanger 1

1 - 55
Student Guide SIPLACE X
Edition 09/2005 8 Collect&Place-Head 20
55
8.5.5 Pneumatic plan for nozzle changer
Fig. 8.5 - 4 Pressure air supply for the nozzle changer
The air pressure supply of the nozzle changer will be assembled by the T-piece as shown in the
picture below. A additional Y- piece is necessary for the optional 2
nd
Nozzle changer carrier.
Fig. 8.5 - 5 Air pressure connection of the nozzle changer
The DLM nozzle changers are connected to 2.5 bar (loopedhose in the picture). The C&P20 noz-
zelchanger is connected to 4.5 bar.
3
4
2
1
Gantry 1 - 4
4
3
2
1
Bulkcase
Feeder
COT 1-4
2,5 bar
adjustable
Nozzle
changer
1 2
34
Nozzle changer
Gantry 1 - 4
2,5 bar
adjustable
Docking unit
1 - 4
5 bar
adjustable
Conveyor
5 bar
adjustable
5 bar
adjustable
1 2 3 4
Compressed air distributor block
Tape cutter
1 - 4
4 3
21
+
nozzle changer
C&P20
(4,5bar)
CAN- Bus connector of nozzle
changer
Air pressure connection of nozzle changer