SiplaceX4_en.pdf - 第548页

1 - 5 S tudent Guide SIPLACE X Edition 09/2005 12 Siplac e X - Head Modularity 5 Fig. 12.1 - 3 Means of deciding between 12 segment C&P head or 6 segmen t C&P head w/o DCA camera Please Note: For the Option Head …

100%1 / 670
1 - 4
Student Guide SIPLACE X
12 Siplace X - Head Modularity Edition 09/2005
4
12.1.1 Production requirements
Please Note:
The reconfiguration of the Siplace X machine should exist for a longer production time of a product
and not occur by the week because the configuration and the calibration of the machine, depend
of the machine type and the number of heads, uses approximately one day. 12
Which decisions must be taken before head exchange?
Fig. 12.1 - 2 Means of deciding between C&P head and Twin head
Please Note:
In the case of a PCB with different component sizes, you should decide for which C&P head install
the 12 segment C&P head or 6 segment C&P head with ir without DCA camera
(see Fig. 12.1 - 3) or the 20 segment C&P head. 12
Only IC`s respective Odd
shape placement?
Mixed fast IC`s respective
Odd shape placement?
Only fast chip`s and IC`s
placement?
X2: Gantry 1 / 3 -->Twin head
X3: Gantry 1 / 4 -->6 Segment C&P head
Gantry 3 -->Twin head
X2: Gantry 1 --> 12 Segment C&P head
Gantry 3 --> Twin head
X3: Gantry 1/4 --> 2x12 or 2x20 Segment
C&P head
Gantry 3 --> 6 Segment C&P head
X4: Gantry 1 / 4 Æ 20 Segment C&P head
Gantry 2 / 3 Æ 6/12 Segment C&P head
X2: Gantry 1 -->C&P head
Gantry 3 -->Twin head
X3: Gantry 1 -->12 Segment C&P head
Gantry 4 -->6 Segment C&P head
Gantry 3 -->Twin head
Yes
Yes
Yes
1 - 5
Student Guide SIPLACE X
Edition 09/2005 12 Siplace X - Head Modularity
5
Fig. 12.1 - 3 Means of deciding between 12 segment C&P head or 6 segment C&P head w/o DCA camera
Please Note:
For the Option Head Modularity please use the retrofitting instruction "Head Reconfiguration kits
00119721- Twin Head Reconfiguration Kit X-Serie
00119760- 12-Seg. C&P Head Reconfiguration Kit digital
00119761- 6-Seg. C&P Head Reconfiguration Kit digital
00119762- C&P20 Head Reconfiguration Kit
On the 6 segment C&P head is a high resolution camera as standard mounted, so you can use
this camera on the 12 segment C&P head for 0201 components and Flip chip‘s.
Component size > 18,7x18,7mm
Component height > 6mm
?
BE weight > 2g?
0201 or BARE DIE
Flip chip placement?
6 segment C&P head
6 segment C&P head with standard
Camera or
12 segment C&P head with the
camera from the 6 C&P head (DCA)
6 segment C&P head
Yes
Yes
Yes
12 Segment C&P head
No
No
No
12 Segment C&P head with
standard camera
Deciding factors about the choice of the C & P heads and the camera types.
1 - 6
Student Guide SIPLACE X
12 Siplace X - Head Modularity Edition 09/2005
6
12.1.2 Head exchange
1. Make a backup for the exist
machine configuration.
2. Machine data - backup with the
Sitest and create a folder
e.g. Backup and store the folder
SRCMA.
4. Confirm the configuration,
machine will shutdown
automatically
Switch off the machine!
6. Mechanical works:
Mount the Head, adapterboard
and Nozzlechanger.
7. Switch ON the machine
Look to the error messages
Set the nozzle on the head and
check the nozzle changer.
Note: Save the zero point correction from the
EEPROM to the Achsver.ma.
Check the firmware!
8. Siplace Pro computer:
Make a copy of the exist basic set
up and configure into the copy the
new head type and
nozzlechanger
Note: As a result the new configuration will be
send to the station.
9. Siplace Pro computer:
Send a placement program, e.g.
with one component to the
station.
10. Station:
Check the axis dynamic and
calibrate all heads and cameras.
11. Station:
Start the production.
Note: Stop the current job from Siplace Pro
before you shutdown the machine.
5. Mechanical works:
Head, Nozzlechanger and
adapterboard exchange.
Note: Don`t change the adapterboard if you
change from C&P6 < -- > C&P12 head. Change
the Servo amplifier and don`t forget the DC/DC
converter for C&P 20 head.
Note: Preparations of the head plate (sealing with grub
screw, attention different length of the head screws)
Height adjustment nozzlechanger and different pressure
air supply for C&P20 head!
C&P20 X-Feeder Docking unit
3. SITEST: Machine configuration
(Head type, nozzle changer,
cameras).