SiplaceX4_en.pdf - 第293页

1 - 65 S tudent Guide SIPLACE X Edition 09/2005 6 Coll ect &Place-Head 6/12 65 6.4.9 Adjustment of mechani cal Position of V alve Drives ➠ If the new valve plungers are used (s. Fig. 6.4 - 13 ), proceed a s follows: …

100%1 / 670
1 - 64
Student Guide SIPLACE X
6 Collect &Place-Head 6/12 Edition 09/2005
64
6.4.8 Determination of Zero Point Correction Star-Axis C&P Head
Fig. 6.4 - 11 Flow chart zero point correction
Menue C&P Heads
Select referring C&P Head
Menue Axes
Select Star axis
Positions
Zero point correction (ZPC) = 0
edit and accept
Axis reference run
disable Star / Z* Axis at axis
controller
Remove sleeve from segment 1
Turn segment 1 to bottom position
Mount Star axis Zero point gauge,
Insert fixing pin into gauge
DLM2 lower Z-Axis, that fixing pin
engage at segment
Select DP- and Star-Axis again
Enter actual position as new
Zero point correction (ZPC)
*
Remove Star zero point gauge
Insert sleeve
Enable Star (Z*) Servo
Execute Axis reference run
check position of the new Zero point-
correction (Segment 1 down)
Save machine data
End
start SITEST
* for DLM2 at HF-Machine:
* ZPC for HF-Machine: divide
actual Position by 2.5
* for DLM2 at HF-Machine:
1 - 65
Student Guide SIPLACE X
Edition 09/2005 6 Collect &Place-Head 6/12
65
6.4.9 Adjustment of mechanical Position of Valve Drives
If the new valve plungers are used (s. Fig. 6.4 - 13), proceed as follows:
Take out one valve plunger and remove the plastic bushing
(2).
Insert the plunger without bushing and carry out the following steps on this segment:
Set the motor position of the valve drives "Pick-up / Placement" and "Ejection" according to the
figure below.
Insert the distance gauge (0.2 mm) between valve plunger and valve casing.
Turn the valve drive to 90° degrees, opposite to its initial position. The excentric of the valve
drive will just touch the inner flange of the valve.
Fix the motor of the valve drive in this position.
Don’t forget to refit the plastic bushing on the plunger.
6
Fig. 6.4 - 12 Mechanical position of the valve drive
6
Fig. 6.4 - 13 New Valve plunger, item.no:00351498-03
2
1
1 - 66
Student Guide SIPLACE X
6 Collect &Place-Head 6/12 Edition 09/2005
66
6.4.10 Air Pressure Values
6.4.10.1 Tools and Devices
A set of slotted screw drivers
Compressed air testing device
6.4.10.2 Adjustment of Air Pressure Values
6
Fig. 6.4 - 14 Adjustment of air pressure values
LEGEND:
(1) Forced air unit
(2) Solenoid valve for air kiss
(3) Adjustment valve for the reject circuit
(4) Adjustment valve for the pick - up / placement circuit
Please Note
:
Use a nozzle type 904 or 914 to adjust the air kiss. Please press in the spring from the nozzle
interface during the measurement and read the value from the display. 6
4
1
2
3