SiplaceX4_en.pdf - 第632页

1 - 65 S tudent Guide SIPLACE X Edition 09/2005 13 MTC 2 65 13.3.5 Converting the power supply T o operate the MTC 2 in the USA or in Japan, the power supply n eeds to be changed from 400 V , 50 Hz to 208/204 V , 50/60 H…

100%1 / 670
1 - 64
Student Guide SIPLACE X
13 MTC 2 Edition 09/2005
64
13.3.4.5 Disengaging mechanism
Tools and accessories 13
1 set of hexagon socket wrenches
Preparatory measures 13
Empty the MTC 2 completely (see the User Manual).
Move the feed axis into the zero position (see section13.3.2.2 ) and engage the driver in the
WTC.
Setting the disengaging mechanism 13
Move the driver over the belt until it lies outside the disengaging mechanism.
Check that the driver in its dead center position engages centrally with the disengaging
aperture when it is moved back.
When the guide roller is pushed through the middle of the aperture, set the position of the
aperture with the 4 securing screws of the disengaging mechanism.
Fig. 13.3 - 26 Setting the disengaging mechanism
Key
1 Driver guide roller in dead center position
2 Disengaging mechanism aperture
3 Disengaging mechanism securing screws
2
3
1
1 - 65
Student Guide SIPLACE X
Edition 09/2005 13 MTC 2
65
13.3.5 Converting the power supply
To operate the MTC 2 in the USA or in Japan, the power supply needs to be changed from 400 V,
50 Hz to 208/204 V, 50/60 Hz.
NOTE
To convert the power supply from 208/204 V to 400 V, the same procedure must be carried out in
the reverse order.
Tools and accessories 13
1 set of screwdrivers
3 additional bridges
13.3.5.1 Procedure
Fig. 13.3 - 27 Electronics board
Key
1 Bridges on the voltage distributor terminal X01
2 Motor protection switch
2
1
1 - 66
Student Guide SIPLACE X
13 MTC 2 Edition 09/2005
66
13.3.5.2 Voltage distributor terminal X01
13
Fig. 13.3 - 28 Voltage distributor terminal X01
Key
1 Bridges on the voltage distributor terminal X01
Removing the three bridges between 2-3, 6-7 and 10-11.
Connect the six bridges between 1-2, 3-4, 5-6, 7-8, 9-10 and 11-12.
13.3.5.3 Motor protection switch
13
Fig. 13.3 - 29 Motor protection switch
Key
1 Rotary regulator of the motor protection switch
Do not switch the rotary regulator of the motor protection switch, if you converting the power
supply. It is always 3.5 A.
-X01
1
2
3
45
6789
10
11
12
11
11
3,5A
5,0A