SiplaceX4_en.pdf - 第170页

1 - 24 S tudent Guide SIPLACE X 4 Services to the machine Edition 09/2005 24 4.2.8.3 How does the emergency stop loop work? The placement system canno t be used in placement mode u ntil all the supply volt ages have been…

100%1 / 670
1 - 23
Student Guide SIPLACE X
Edition 09/2005 4 Services to the machine
23
Start Button Loop 4
The start button loop consists of 6 contacts and they are switched in parallel mode.
If 1 ore more start button is pressed, the contact is closed and the 24 V signal sets an input on
CAN I/O module in section 4 and shows, that any start button is pressed.
Fig. 4.2 - 17 start button loop
24V
stop button
PCB- output
right
stop button
PCB- output
left
X1qa_startbutton
start button
PCB- input
right
X11qa_1
X12qa_1
X11ra_1
X
1
q
a
_
2
4
V
24V
24V
X73qa_1
X73ra_1
start button
right
(pneumatic)
X10qa_1
24V
X12ra_1
X
1
r
a
_
2
4
V
X10qa_2
X11qa_5
X12qa_5
X11ra_5
X12ra_5
start button
left
(power supply)
X9qa_1 X9qa_2
X1ra_startbutton
C
A
N
I
/
O
-
m
o
d
u
l
e
s
u
b
d
i
s
t
r
i
b
u
t
e
r
,
s
e
c
t
i
o
n
4
3
4
Eingang
cable term: 03002521
X4rb_1
sub distributer, section 4
main distributer, section 2
sub distributer, section 4
main distributer, section 2
start button
PCB- input
left
1 - 24
Student Guide SIPLACE X
4 Services to the machine Edition 09/2005
24
4.2.8.3 How does the emergency stop loop work?
The placement system cannot be used in placement mode until all the supply voltages have been
enabled by the protective circuit. The following conditions must also be fulfilled:
4
All four component change-over tables must be docked.
All covers must be closed.
Both emergency stop push-buttons must be released.
The minimum air pressure must be present.
The software enable signal must be ready.
The Message ’
Security Loop OK’ must be sent (for GND on X6 on SSK, CAN I/O output)
24 V must be present at the start button.
After the start button is pressed, the SSK combinaton activates the following voltages
: _ 4
secundary circuit 250 V for servo X/Y axis (via K2, K3, K4).
secundary circuit 150 V for star axis.
servo unit receives ’Servo Enable’ signal for servo amplifier (K4.5)
The message
’Ctrl_On’ must be sent to CAN I/O (24V from axis unit after receiving the
’servo enable)
34 V operating voltage for the transport handling.
24 V operating voltage for the tape cutter.
M_X/Y: +24 V for K3 and K4
M_tape cutter: +24 V for K2
1 - 25
Student Guide SIPLACE X
Edition 09/2005 4 Services to the machine
25
4.2.9 The Safety Combination (K6 Relay)
Legend
1. power for transport 34 VDC from T2
2. power 24 VDC input from power supply DC/DC converter.
3. input from emergency stop loop (24 VDC)
4. message ready to SLIO (SSK is fine).
5. software release (24 VDC when start button pressed and SW release signal is given).
6. GND for SSK (X6), from Message ’security loop OK’
7. start button pressed (24 VDC form start button).
8. M_X/Y: 24 VDC from SSK (power for K3 and K4).
9. power for transport 34 VDC from SSK
10. M_tape cutter: 24 VDC for contactor K2 and power for tape cutter (24 VDC)
About SSK K6 4
Contactor K6 is an industry standard safety combination contactor. Internally it consists of 3 relays
which are configured in a complex fashion to give maximum protection in a fail safe mode. Unfor-
tunately, for ease of understanding, these internal relays are labeled K1', K2' & K3'. The status of
the contactor is indicated by LEDs labeled as H1, H2 and H3.
When the contactor is in an energized state internal relays K2' and K3' are energized, relay K1' is
de-energized. This status closes the contacts 13 and 14, 23 and 24, 33 and 34.
IWhen this status is achieved K6 can be said to be ‚ON' and the 3 LEDs H1, H2 and H3 are all lit.
L+ X1 X 3 X5 X7 X9 X11
L- X2 X4 X 6 X8 X10
1
2
3
4
5
6
7
8
9
10
auxillary contact
K1.4 K2.4 K3.4 K4.4
K5
SSK K6
power / channel 1 / channel 2
H1 H2 H3
SSK 43
SSK 53
SSK 54
SSK 44
K5K5
K5
K6