1 - 37 S tudent Guide SIPLACE X Edition 09/2005 1 1 Sitest 37 Axis dat a 11 Fig. 1 1.2 - 22 head modularity - axis data (1) Here you can overwrite the Z- and st ar axis data from the head eprom to th e machine dat a and …

1 - 36
Student Guide SIPLACE X
11 Sitest Edition 09/2005
36
11.2.17.3 Head modularity Siplace X
– Choose "Settings" from the Sitest- menu bar, afterwards "Head exchange"
Head data 11
Fig. 11.2 - 21 head modularity - head data
(1) At the head exchange the corresponding head type gets select and set here.
(2) At the head exchange the corresponding camera type of the head type gets select and set
here.
(3) Here are shown the head data of the installed head. The current BIOS and application version,
the head type and the camera type of the installed head.
1
2
3

1 - 37
Student Guide SIPLACE X
Edition 09/2005 11 Sitest
37
Axis data 11
Fig. 11.2 - 22 head modularity - axis data
(1) Here you can overwrite the Z- and star axis data from the head eprom to the machine data and
the other way round.
Function 11
Fig. 11.2 - 23 head modularity - function
(1) After the head was changed, it is possible to calibrate the changed head with help of the head
exchange menu. Of course it is also possible to calibrate the other heads with this function. Basicly
you can also calibrate the new head, and already installed heads in Sitest menu "Calibrate ma-
chine..." and then "All heads and cameras..."
(2) The same is valid here, see (1). After the head exchange you can directly do a head- map-
ping.You also find the function head- mapping in Sitest menu "Calibrate machine..." and then
"Head- Mapping".