SiplaceX4_en.pdf - 第365页
1 - 49 S tudent Guide SIPLACE X Edition 09/2005 7 T win-Head 49 TWIN- head - View fo r D-Axis 90 degree 7 Fig. 7.6 - 13 Dynamic signals D-axis 90 degree rotation TWIN- head - View for D-Axis 180 degree Fig. 7.6 - 14 Dyna…

1 - 48
Student Guide SIPLACE X
7 Twin-Head Edition 09/2005
48
7.6.4.2 Test setup
Please Note::
The test setup for the D-Axis is the same as the Z-Axis
The axis dynamic is tested on different distances.
SITEST 7 ➠ Select "TWIN- head" ==> "Axis functions"
==> Select the "Segment" ==> Select "DP-Achse"
==> "Axis continuous run"
==> Edit values and accept:
target position: 1000
1/100°
= 10°=10000 digits);
Mode: absolut.
Waiting time: 200ms 7
➠ If necessary, press the START button.
TWIN- head - View for D-Axis 10 degree
Fig. 7.6 - 12 Dynamic signals D-xis 10 degree rotation
7
Positioning time: approx. 90ms +/- 10 Distance 10000 digits
Current nominal
Deviation of pos.
End signal
200mV/Div
500mV/Div
50ms/Div
5V/Div

1 - 49
Student Guide SIPLACE X
Edition 09/2005 7 Twin-Head
49
TWIN- head - View for D-Axis 90 degree
7
Fig. 7.6 - 13 Dynamic signals D-axis 90 degree rotation
TWIN- head - View for D-Axis 180 degree
Fig. 7.6 - 14 Dynamic signals D-axis 180 degree rotation
Positioning time:approx. 150ms +/- 20ms, Distance 90000 digits
Current nominal
Deviation of pos.
End signal
200mV/Div
500mV/Div
50ms/Div
5V/Div
Positioning time: approx.190ms +/- 20ms Distance180000 digits
Current nominal
Deviation of pos.
End signal
200mV/Div
500mV/Div
50ms/Div
5V/Div