SiplaceX4_en.pdf - 第573页

1 - 6 S tudent Guide SIPLACE X 13 MTC 2 Edition 09/2005 6 13.1.4.2 Electrical connections 13.1.4.3 Noise emission information 13.1.4.4 Permitted ambient conditions Supply voltage 3 x 400 V~, 50 Hz (Europe) 3 x 208 V~, 60…

100%1 / 670
1 - 5
Student Guide SIPLACE X
Edition 09/2005 13 MTC 2
5
13.1.4 Technical data
13.1.4.1 Dimensions, weight, miscellaneous data
Tower 1 (XL) Tower 2
Dimensions (L x W x H) 1340 x 610 x 1490/1660 mm
Weight (basic configuration) approx. 500 kg (incl. cassettes and WTCs)
Weight (set up completely) approx. 534 kg (with components)
Weight (moving mass) approx. 80 kg approx. 43.5 kg
Cassette size (L x W x H) 391.2 x 305.6 x 93.3 mm 352.7 x 154.8 x 133.8 mm
Cassette weight
(set up completely)
approx. 11 kg approx. 7.5 kg
WTC size (L x W x H) 386.5 x 295.8 x 11.1 mm 371 x 146 x 10.1 mm
Pitch between cassettes 96 mm 135 mm
Pitch between levels 12 mm 11.8 mm
Vertical travel 444 mm (1st through 40th
WTC)
511.2 mm (1st through 40th
WTC)
Horizontal travel approx. 647 mm approx. 638 mm
(between removal and transfer positions)
Storage capacity 30 WTC XL with 40 WTC with
60 JEDEC or 30 special
WPTs max. size
40 JEDEC WPT
Changeover time (over 5 lev-
els)
approximately 2 s approximately 1.5 s
Maximum component height
(incl. WTC)
30 mm 15.5 mm
(for WPT height > 7.62 mm, 1 level must remain free,
for WPT height > 12.19 mm, 2 levels must remain free)
Max. floor load
(set up completely)
6.93 kg/cm2 or 356 kg/cm2
per foot per roller
Tab. 13.1 - 1
1 - 6
Student Guide SIPLACE X
13 MTC 2 Edition 09/2005
6
13.1.4.2 Electrical connections
13.1.4.3 Noise emission information
13.1.4.4 Permitted ambient conditions
Supply voltage 3 x 400 V~, 50 Hz (Europe)
3 x 208 V~, 60 Hz (USA)
Total power 1.5 kW
Rated current 2.7 A for 3 x 400 V~
4.2 A for 3 x 208 V~
Fuse rating 3 x 16 A
Rated current consumption by the
largest consumer
2 A
Tab. 13.1 - 2
Maximum noise level 74 dB (A)
Tab. 13.1 - 3
Room temperature between 15°C and 35°C
Humidity 30 - 75%
(on average no higher than 45%, to prevent conden-
sation on the machine at all times.)
Tab. 13.1 - 4
1 - 7
Student Guide SIPLACE X
Edition 09/2005 13 MTC 2
7
13.1.5 Safety information
13.1.5.1 Warning and information labels on the MTC 2
CAUTION
The following pages contain only the most important safety information. Please observe the safety
instructions detailed in the current operating instructions.
Fig. 13.1 - 4 Location of the warning labels on the MTC 2 (right-hand side)
Key
1see Abb. 13.1 - 6 7see Abb. 13.1 - 12
2see Abb. 13.1 - 7 8see Abb. 13.1 - 13
3see Abb. 13.1 - 8 9see Abb. 13.1 - 14
4see Abb. 13.1 - 9 10 see Abb. 13.1 - 15
5see Abb. 13.1 - 10 11 see Abb. 13.1 - 16
6see Abb. 13.1 - 11
1
5
7
8
11
2
6
3
10
5