SiplaceX4_en.pdf - 第299页
1 - 71 S tudent Guide SIPLACE X Edition 09/2005 6 Coll ect &Place-Head 6/12 71 6.5.3 Control nozzle changer on the C&P heads The nozzle changer are controlled via CAN Bus. Dependin g on the location at the mach i…

1 - 70
Student Guide SIPLACE X
6 Collect &Place-Head 6/12 Edition 09/2005
70
6.5.2 Nozzle changer for 6 segment C&P head
The nozzle changer for a 6 segment C&P head consists of at least one, and up to twelve maga-
zines, each with six nozzle garages. The magazines are seated on a common support and each
magazine is centered using two parallel pins and fixed in place with a spring hook.
Magazines for the 9xx and 8xx nozzle types can be set up. The magazine types can be arranged
as required.
Fig. 6.5 - 2 Nozzle changer 6 segment C&P head
Fig. 6.5 - 3 Description of the positions nozzle changer
Magazin for 6
nozzle Typ 8xx
Magazin for 6
nozzle Typ 9xx
Transport direction
(1) Component reject position
(2) Nozzle reject position

1 - 71
Student Guide SIPLACE X
Edition 09/2005 6 Collect &Place-Head 6/12
71
6.5.3 Control nozzle changer on the C&P heads
The nozzle changer are controlled via CAN Bus. Depending on the location at the machine the
SLIO at Main- or Sub-Distributor is used. At HF-machine version ’A’ and SIPLACE X the nozzle
changer is controlled via the "One Wire Bus". Solenoid valves activate the pneumatic rotary drives
to open or close the nozzle changer.
Fig. 6.5 - 4 Pressure air supply for the nozzle changer (pneumatic unit)
3
4
2
1
Gantry 1 - 4
4
3
2
1
Bulkcase
Feeder
COT 1-4
2,5 bar
adjustable
Nozzle
changer
1 2
34
Nozzle changer
Gantry 1 - 4
2,5 bar
adjustable
Docking unit
1 - 4
5 bar
adjustable
Conveyor
5 bar
adjustable
5 bar
adjustable
1 2 3 4
Tape cutter
1 - 4
4 3
21