Student Guide SIPLACE X
5 Gantry Edition 09/2005
22
Test procedure 5
Connect the track signal tester on the incremental encoder.
Switch "ON" the main switch
Connect the oszilloscope on the track signal tester.
Set the switch to "Oszilloscope calibrate" on the track signal tester.
Positioning the signal to the middle from the upper half of the display. (see picture below)
Fig. 5.4 - 2 Initinal start point to measure the zero pulse.
Please Note:
Check the first zero pulse which you need for the reference run on the incremental scale.
Move by hand the gantry over the first zero pulse.
It should appear the following picture on the oscilloscope.
Fig. 5.4 - 3 Adjustment of the incremental encoder correct
Initial start position
1. In the Tolerance
space of - 0,3 V you
don‘t have an inter-
ference pulse.
2. The analog zero
pulse have to over
the tolerance space
more then 0,3V
analog zero pulse
digital zero pulse
1
2
1 - 23
Student Guide SIPLACE X
Edition 09/2005 5 Gantry
23
Fig. 5.4 - 4 Incremental encoder wrong adjusted or poluted zero pulse
Legend
5.4.1.2 Measurement the digital zero pulse signal
Please Note: Also for checking the zero pulse you can use the BNC connector from the axis test
box (inverse signal).
On the connectors X10 and X24 on gantry -and headinterface can you check the digital Signals.
(Y-Axis, more time to dismounting the covers)
Fig. 5.4 - 5 Test setup to check the digital zero pulse and track signals
(1) analog track signal A and B (2) analog zero pulse
(3) digital zero pulses
1
2
3
Test setup for digital zero pulse and track signals
Measurment system X/Y Axis
Track A/B/N
Resolution incremental scale
1 Digit= 1µm
Track signal
tester
BNC-cable
Siplace HF
Board
Test connector
Ribbon cable
1 - 24
Student Guide SIPLACE X
5 Gantry Edition 09/2005
24
X10 on the Gantry Interface Y-axis 5
X24 on the head interface X-axis 5
Please Note:
The measurement procedure for measurment the digital zero pulse is the same as the analog zero
pulse.
Connector:
Pin 1 Ground
Pin 2 Track A
Pin 3 Track A\
A\ mean inverted A
Pin 4 Ground
Pin 5 Track B
Pin 6 Track B\
Pin 7 +5V
Pin 8 Track N
Pin 9 Track N\
Pin 10 Key
Connector:
Pin 1 Ground
Pin 2 Track A
Pin 3 Track A\
Pin 4 Ground
Pin 5 Track B
Pin 6 Track B\
Pin 7 +5V
Pin 8 Track N
Pin 9 Track N\
Pin 10 Key