00195741-0102_UM_D1_D2_SR605_EN.pdf - 第122页
3 Technical data for the machine User Manual SIPLACE D1/D2 3.7 Gantry system From software version SR.605.xx 07/2008 EN Edition 122 3.7 Gantry system 3.7.1 Position of the gantries 3 Fig. 3.7 - 1 Position of the gantries…

User Manual SIPLACE D1/D2 3 Technical data for the machine
From software version SR.605.xx 07/2008 EN Edition 3.6 Placement head
121
Nozzle types 5xx (standard)
4xx + adapter
8xx + adapter
9xx + adapter
5xx (standard)
4xx + adapter
8xx + adapter
9xx + adapter
5xx (standard)
4xx + adapter
8xx + adapter
9xx + adapter
X/Y accuracy
c
± 37.5 µm/3σ
± 50 µm/4σ
± 37.5 µm/3σ
± 50 µm/4σ
± 30 µm/3σ
± 40 µm/4σ
Angular accuracy ± 0.053°/3σ
± 0.071°/4σ
± 0.053°/3σ
± 0.071°/4σ
± 0.053°/3σ
± 0.071°/4σ
Component range 99.8% 99.9% 99.8%
Component camera type 36 33 25
Illumination levels 6 6 6
Possible illumination level
settings
256
6
256
6
256
6
a) Please note that the range of components that can be placed is also affected by the pad geometry, customer-spe-
cific standards, component packaging tolerances and component tolerances.
b) If standard nozzles are used
c) The accuracy value was measured using the vendor-neutral IPC standard

3 Technical data for the machine User Manual SIPLACE D1/D2
3.7 Gantry system From software version SR.605.xx 07/2008 EN Edition
122
3.7 Gantry system
3.7.1 Position of the gantries
3
Fig. 3.7 - 1 Position of the gantries
(1) Gantry 1 (D1 and D2)
(2) Gantry 2 (D2)
The gantry system consists of two functional groups
–X axis and
–Y axis

User Manual SIPLACE D1/D2 3 Technical data for the machine
From software version SR.605.xx 07/2008 EN Edition 3.7 Gantry system
123
3.7.2 Structure of the X axis
3
Fig. 3.7 - 2 Structure of the X axis
The X axis essentially consists of the following main modules:
– Gantry arm (1)
– Head mount (2)
– Linear measuring system (3)
– X axis guide system (4)
– X axis three-phase AC servomotor (5)
The head mount holds the following components:
– Sub-gantry camera (camera for the PCB vision module)
– Head board
– Measuring head for the X axis measuring system
– Collect&Place head (SIPLACE D2)
– Collect&Place head and Pick&Place head (SIPLACE D1)