00195741-0102_UM_D1_D2_SR605_EN.pdf - 第281页

User Manual SIPLACE D1/D2 6 Station extensions From software version SR.605.xx 07/2008 EN Edition 6.2 Waffle-pack changer (WPC) 281 6.2.3.3 Permitted environment al factors 6.2.4 Inst allation notes for the WPC The WPC c…

100%1 / 334
6 Station extensions User Manual SIPLACE D1/D2
6.2 Waffle-pack changer (WPC) From software version SR.605.xx 07/2008 EN Edition
280
6.2.3 Technical data
6.2.3.1 Dimensions, weight
6.2.3.2 Electrical ratings
Dimensions (L x W) 1560 x 360 mm²
Height
830 mm ± 15 mm PCB conveyor height
900 mm ± 15 mm PCB conveyor height
930 mm ± 15 mm PCB conveyor height
950 mm ± 15 mm PCB conveyor height
1360 mm ± 15 mm
1430 mm ± 15 mm
1460 mm ± 15 mm
1480 mm ± 15 mm
Weight approx. 240 kg
Load per unit area 4.19 kN/m²
Dimensions of the waffle-pack tray carrier (L x W x H) 360 x 260 x 6 mm³
Weight of the waffle-pack tray carrier 0.8 kg
Dimensions of the waffle-pack tray, including components 341 x 235 x 15 mm³
max. 341 x 235 x 23 mm³
Weight of the waffle-pack tray carrier, including waffle-pack tray
and components max. 1.2 kg
Storage capacity max. 28 WTC
Total weight of the 28 waffle-pack tray carriers 27.6 kg
Weight of magazine storage unit, waffle-pack tray carrier, waffle-
pack trays and components max. 50 kg
Changeover time for waffle-pack tray carriers
over 1 level
over 10 levels
over 27 levels
1.9 s
2.3 s
2.9 s
Supply voltage 3 x 200 VAC ± 5%; 50/60 Hz (Japanese version)
3 x 208 VAC ± 5%; 50/60 Hz (U.S.A. version)
3 x 230 VAC ± 5 %; 50/60 Hz
3 x 380 VAC ± 5 %; 50/60 Hz
3 x 400 VAC ± 5 %; 50/60 Hz (European version)
3 x 415 VAC ± 5 %; 50/60 Hz
Nominal apparent power 800 VA
Rated current 0.7 A at 3 x 400 VAC
Fuse 3 x 10 or 3 x 16 A
User Manual SIPLACE D1/D2 6 Station extensions
From software version SR.605.xx 07/2008 EN Edition 6.2 Waffle-pack changer (WPC)
281
6.2.3.3 Permitted environmental factors
6.2.4 Installation notes for the WPC
The WPC can be docked into the right-hand side of the machine at location 1 of the D1 machine.
Install the upgrade kit on location 1. Then dock in the WPC. If you use the WPC at another loca-
tion, the free location may be set up with a component trolley once more.
Room temperature Between 15°C and 35°C
Atmospheric humidity 30 - 90% at 20°C
6 Station extensions User Manual SIPLACE D1/D2
6.2 Waffle-pack changer (WPC) From software version SR.605.xx 07/2008 EN Edition
282
6.2.5 Dimensions of the D1 machine with WPC
6
Fig. 6.2 - 1 Dimensions of the D1 machine with WPC