00195741-0102_UM_D1_D2_SR605_EN.pdf - 第66页
2 Operational safety User Manual SIPLACE D1/D2 2.6 Safety equipment From software version SR.605.xx 07/2008 EN Edition 66 2.6 Safety equipment 2.6.1 Protective covers 2 Fig. 2.6 - 1 Protective covers - viewed from the in…

User Manual SIPLACE D1/D2 2 Operational safety
From software version SR.605.xx 07/2008 EN Edition 2.5 Safety instructions for operating the machine
65
2.5.10 Safety instructions for the tape cutter
2
Fig. 2.5 - 6 Safety instructions for the tape cutter
WARNING RISK OF CUTTING! 2
→ Never reach down into the used tape channel (Pos. 1 in Fig. 2.5 - 6
) from above with bare
hands, even if the machine is switched off.
→ Similarly, even when the machine is switched off, do not reach up from below with bare hands
into the ejection opening of the tape cutter (Pos. 2 in Fig. 2.5 - 6
), e.g. to remove waste used
tape.
→ To remove waste used tape, it is essential to switch the machine off first and put on very sub-
stantial protective gloves, as the tape cutter bars are extremely sharp.

2 Operational safety User Manual SIPLACE D1/D2
2.6 Safety equipment From software version SR.605.xx 07/2008 EN Edition
66
2.6 Safety equipment
2.6.1 Protective covers
2
Fig. 2.6 - 1 Protective covers - viewed from the input side
(1) Protective covers
(2) Safety panels
(3) Cover flap on the input belt
(4) Hand guard on the input belt

User Manual SIPLACE D1/D2 2 Operational safety
From software version SR.605.xx 07/2008 EN Edition 2.6 Safety equipment
67
2
Fig. 2.6 - 2 Cover flap on the output belt
(1) Cover flap on the output belt - swivels inwards
The traveling range of the gantries has two protective covers that can be swung upwards. There
are side screens to prevent access to the inside of the machine from the side. The lift-up hinged
cover over the input belt of the PCB conveyor, the hand guard on the input belt and the hinged
cover flap that swivels inwards on the output belt all prevent access to the PCB conveyor.
Function 2
The power supply to the gantry axes is interrupted immediately if one of the protective covers is
lifted up or the cover flap on the PCB conveyor is raised or swiveled in. The gantry axes stop mov-
ing. The message "Close cover" is displayed on the screen.
→ Close the protective covers and press one of the start buttons to continue placement.