00195741-0102_UM_D1_D2_SR605_EN.pdf - 第82页

2 Operational safety User Manual SIPLACE D1/D2 2.7 Residual voltages and discharge times in the machin e From software version SR.605.xx 07/2008 EN Edition 82 Fig. 2.7 - 2 Measuring points on the power supply unit 2

100%1 / 334
User Manual SIPLACE D1/D2 2 Operational safety
From software version SR.605.xx 07/2008 EN Edition 2.7 Residual voltages and discharge times in the machine
81
2.7 Residual voltages and discharge times in the
machine
If the EMERGENCY STOP button is pressed or the machine is switched off, the 200 VDC link volt-
age for the gantry axes and the 150 VDC link voltage for the star axes are reduced to harmless
residual voltages in a very short time.
WARNING 2
The machine is supplied with 3 x 200 VAC, 3 x 208 VAC, 3 x 230 VAC, 3 x 380 VAC,
3 x 400 VAC or 3 x 415 VAC ± 5 %, 50/60 Hz main power voltage. This means that some parts of
the system carry potentially lethal voltages - even when switched off at the main power switch.
Incorrect handling of the machine can therefore result in death or severe injury or considerable
damage to equipment.
Always follow the applicable accident prevention and DIN regulations (particularly DIN EN 60
204, part 1).
The guards over the power supply unit and the axis unit must ONLY be opened by appropri-
ately qualified and trained personnel.
2
Fig. 2.7 - 1 Power supply unit
(1) Padlock with bolt in the cover
(2) Main power switch
(3) Power supply unit behind the cover
2 Operational safety User Manual SIPLACE D1/D2
2.7 Residual voltages and discharge times in the machine From software version SR.605.xx 07/2008 EN Edition
82
Fig. 2.7 - 2 Measuring points on the power supply unit
2
User Manual SIPLACE D1/D2 2 Operational safety
From software version SR.605.xx 07/2008 EN Edition 2.7 Residual voltages and discharge times in the machine
83
2.7.1 Operating voltages, residual voltages and discharge times after pressing
the emergency stop button
2
2
2
2
2
2.7.2 Residual voltages and discharge times after switching off at the main switch
2
CAUTION 2
To avoid losing data, assess the following criteria before switching off your machine (apart from in
emergencies):
Has the machine finished transmitting machine, setup and panel data?
Has the machine finished processing the PCB?
Has the machine completed the run-up phase?
Pin X14 and connector X8:1
measured to X15 (GND)
Voltage in
normal mode
Residual voltage
after
EMERGENCY
STOP
Discharge
times
X14 + 198 VDC < 60 VDC 4 s
X8:1 + 132 VDC < 60 VDC 1 s
Pin X14 and connector X8:1
measured to X15 (GND)
Residual voltages when
main power switch is off Discharge times
X14 < 60 VDC 4 s
X8:1 < 60 VDC 1 s