00195741-0102_UM_D1_D2_SR605_EN.pdf - 第56页
2 Operational safety User Manual SIPLACE D1/D2 2.3 Laser classification Fr om software version SR.605.xx 07/2008 EN Edition 56 2.3 Laser classification 2.3.1 Laser class 1 2.3.1.1 Classification of the whole mac hine 2 P…

User Manual SIPLACE D1/D2 2 Operational safety
From software version SR.605.xx 07/2008 EN Edition 2.2 Warning labels
55
2.2.8 Warning label on the CEKON plug
2
Pos. W 211 in Fig. 2.2 - 12 (number per machine: 1)
2
Fig. 2.2 - 12 Warning label W211 on the CEKON plug
Pos. W211, item no. 03009351-01
2
RESIDUAL VOLTAGE!
Wait 30 seconds after disconnecting the main power plug from the mains to
allow any residual voltages to dissipate.
NAFTA region: Hazardous Voltage
Residual power at plug prongs and wire ends will cause death or serious in-
jury. Avoid contact with power plug and/or wire ends for 30 seconds

2 Operational safety User Manual SIPLACE D1/D2
2.3 Laser classification From software version SR.605.xx 07/2008 EN Edition
56
2.3 Laser classification
2.3.1 Laser class 1
2.3.1.1 Classification of the whole machine
2
PLEASE NOTE: 2
Modules in laser classes 1 and 1M are not identified.
2.3.1.2 Classification of the camera systems
2
2.3.2 Laser class 1M
Do not look directly at this with optical instruments!
2
2
All installed camera systems and the whole machine when ready
for operation are assigned to laser class 1.
The laser classes are determined according to DIN EN 60825-
1:2001
2
The following camera systems are assigned to laser class 1:
– PCB camera, type 24, digital
– Component cameras for the SIPLACE Pick&Place head:
– Component camera, stationary, P&P, type 36, 32 x 32, digital
– Component camera, stationary, P&P, type 33, 55 x 45, digital
– Component camera, stationary, P&P, type 25, 16 x 16, digital
2
The following camera systems are assigned to laser class 1M:
– C&P CO camera, type 28, 18 x 18 on the 12-segment Collect&Place head
– C&P CO camera, type 29, 27 x 27 on the 6/12-segment Collect&Place head
– C&P CO camera, type 38, 16 x 16 on the 12-segment Collect&Place head

User Manual SIPLACE D1/D2 2 Operational safety
From software version SR.605.xx 07/2008 EN Edition 2.4 Safety instructions for transporting the machine
57
2.3.3 Laser class 2
The following modules are assigned to laser class 2:
– Laser light barrier, placement area 1 in the PCB conveyor
– Laser light barrier, placement area 2 in the PCB conveyor
– PCB barcode scanner
– Coplanarity laser module
2
2.4 Safety instructions for transporting the machine
2
Use a fork-lift truck with the following specification to carry the machine:
Fork length: min. 1800 mm
Carrying power: min. 3000 kg
Clear width between forks: min. 350 mm 2
WARNING
RISK OF TIPPING 2
If the required specification cannot be applied to the fork-lift, there is a risk that the fork-lift will tip
over when carrying the machine.
Transporting the machine is described in chapter 4, Section 4.1, page 185.
2
Laser radiation
Do not look into beam!