FUJI NXT Programming Manual QD004-18.pdf - 第130页

4. Part Data Settings QD004-18 120 NXT Programming Manual Vision Type 62 Resistors networ ks, MELFs Enter the body size in part data. There is no need to ente r element information. The reference point for th e part is t…

100%1 / 220
QD004-18 4. Part Data Settings
NXT Programming Manual 119
Vision type number details
The following section provides an explanation of the processing method for each vision
type.
Vision Type 18 MPA (Multi-Purpose Algorithm)
Vision Type 19 MPA (Multi-Purpose Algorithm) with lead checks
Use this vision type for irregularly shaped parts for which other vision types cannot be used.
Use VPDplus to create the vision data.
Vision Type 60 Rectangular Chips
Enter the body size in part data. There is no need to enter element information. The
reference point for the part is the part center.
Vision Type 61 Tantalum Spragues
Vision Type 63 Tantalum Spragues (polarity check performed)
Enter the body size in part data. There is no need to enter element information. The
projection of the tantalum sprague must be included in the body size. The reference point
for the part is the part center. To perform a polarity check, the supply direction must be
correctly specified in part data.
Rectangular chip
Body size X
Direction 0 deg
90 deg
Supply direction
Body size
Y
Tantalum sprague
Direction 0 deg 90 deg 180 deg 270 deg
Body size X
Body
size Y
Supply direction
4. Part Data Settings QD004-18
120 NXT Programming Manual
Vision Type 62 Resistors networks, MELFs
Enter the body size in part data. There is no need to enter element information. The
reference point for the part is the part center.
Vision Type 65 Aluminum electrolytic capacitors
Enter the body size in part data. There is no need to enter element information. Be sure
to include projections such as leads in the body size. The reference point for the part is the
part center.
Resistor networks
Glass tube diodes MELF
Direction 0 deg
90 deg
Body size X
Body size X
Body size X
Body
size
Y
Body
size
Y
Supply direction
Body
size
Y
Body size X
Body
size
Y
Aluminum electrolytic capacitor
Direction 0 deg
90 deg
Supply direction
Body size X
Body
size
Y
QD004-18 4. Part Data Settings
NXT Programming Manual 121
Vision Type 66 Rectangular Chips (skewed pickup check function)
Enter the body size in part data. There is no need to enter element information. The
reference point for the part is the part center. This performs a check to ensure that the part
is not picked up skewed.
Vision Type 70 (75) Power transistors
It is necessary to enter the body size and element information in part data. The reference
point is the body center with vision type 70, while the reference point is the part center with
vision type 75. Create separate element data for leads of different length and width. If the
leads have a large cuts at the corners then it is necessary to select the [Don’t inspect] option
for the [Result] group for that element.
Rectangular chip
Body size X
Direction 0 deg
90 deg
Supply direction
Body size
Y
Power transistor
Element 1
Direction 0 deg 90 deg 180 deg 270 deg
Element
Body
size
Y
Body size X
Element 2
Element 3
Supply direction
Note: Create separate
element data for leads
of different length and
width.
Element 4