Specifying the available nozzles for a machine
By setting which nozzles are available for the NXT machine, only the nozzles specified as
being available display when a user is selecting a nozzle for a position. This ensures that
a nozzle is not accidentally selected that is not available and reduces the amount of choices
in the nozzles drop-down list, thus allowing easier selection. It is also possible to specify
the quantity of nozzles.
1. There are several tabs at the bottom of the [Machine Configuration] pane. Select the
[Nozzle Available] tab and the available nozzles for the machine display.
2. Double-click in the data cell under [Available] that is on the row for the desired nozzle
and a drop-down list box displays. Select “Yes” if that nozzle is available for that
machine, or “No” if the nozzle is not available for that machine. Repeat until all of the
available and unavailable nozzles have been specified.
3. If you want to specify the quantity of nozzles present, then scroll the window to the right
and then specify the quantity of nozzles available in the [Qty] column. If left at 0 and the
nozzle available setting is “Yes”, then it is considered that there is no limit on the nozzle
quantity.
01PRG-0058E

QD004-18 3. Job Builder
NXT Programming Manual 29
Specifying the feeder setup for an NXT
Making settings in the [Feeder Setup] tab is not normally necessary. The feeder setup will
be automatically reconfigured based upon the available feeders during optimization.
01PRG-0059E

3. Job Builder QD004-18
30 NXT Programming Manual
Specifying the available feeders for a machine
By setting which feeders are available for the NXT machine, an unavailable feeder will not
be selected when optimization is performed. In addition, it is possible to specify the quantity
of each feeder type available so the optimizer will not use more feeders of a certain type
than that is available.
1. There are several tabs at the bottom of the [Machine Configuration] pane. Select the
[Feeder Available] tab and the available feeders for the machine display.
2. Double-click in the data cell under [Available] that is on the row for the desired feeder
and a drop-down list displays. Select the “Yes” if that feeder is available for that
machine, or “No” if the feeder is not available for that machine. Repeat until all of the
available and unavailable feeders have been specified.
3. If you want to specify the quantity of feeders present, then scroll the window to the right
and then specify the quantity of feeders available in the [Qty] column. If left at 0 and the
feeder available setting is “Yes”, then it is considered that there is no limit on the feeder
quantity.
The new settings will take effect the next time optimization is performed.