XP Type II 工程师培训手册 (2.0).pdf.pdf - 第124页
FK-9F98-34 XP T ype II Series T raining T est for Service Engineers Edition 2.0 XP242E – Chapter 3 S t atic Accuracy Me asurement Page 6 of 6 NOTES: Fuji Machine Mfg. Co., Ltd. Okazaki SMT Equipment Quality Assurance Dep…

FK-9F98-34 XP Type II Series Training Test for Service Engineers
Edition 2.0 XP242E – Chapter 3 Static Accuracy Measurement Page 5 of 6
3.5 Nozzle Station Parallelism and Flatness
Nozzle station parallelism measurement
1. Attach a dial gauge to the placing head (an
extension bar necessary).
2. Measure the parallelism from the reference
position in the X- and Y-direction.
Note: if the value is out of the tolerance, please
contact FUJI.
Nozzle station flatness measurement
+-
0
Measure the side of
the nozzle station
0
140
280
Tolerance: 0.06mm / 280mm
B
A
D
C
1. Attach the dial gauge to the placing head (an extension
bar is necessary).
2. Measure the height of the four corners of the nozzle
station, ensuring any deviation is within 0.06 mm.
Note: If the value is out of the tolerance, please contact
FUJI.
0
Tolerance: Deviation 0.06mm
3.6 Backlash
• Equipment: Lever type dial gauge (0.002mm).
1. Set the dial gauge to the X and Y-axes. Turn the 200V servo power ON. Measure any
backlash in the X and Y axes movement.
2. For the Q-axis, adjust it so there is no backlash.
Tolerance: within 0.010 mm
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
3 – 5 CS Section

FK-9F98-34 XP Type II Series Training Test for Service Engineers
Edition 2.0 XP242E – Chapter 3 Static Accuracy Measurement Page 6 of 6
NOTES:
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
3 – 6 CS Section