XP Proper Data ListType-II vol.3 Issue Date:2003/6/17 Item XP142 X P242 Input Rang e Explanation Editing Reboot Z_Nzl9PickUpOfs t = 00 None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups. Calibrati…

XP Proper Data ListType-II vol.3
Issue Date:2003/6/17
Item XP142
X
P242 Input Rang
e
Explanation
Editing
Reboot
______NOZZLE_DIAMETER_____
_
=
__Nzl1Diamete
r
= 00
0~99.9 Sets the nozzle 1 diameter (mm)
User Cannot Edit
__Nzl2Diamete
r
= 00
0~99.9 Sets the nozzle 2 diameter (mm)
User Cannot Edit
__Nzl3Diamete
r
= 00
0~99.9 Sets the nozzle 3 diameter (mm)
User Cannot Edit
__Nzl4Diamete
r
= 00
0~99.9 Sets the nozzle 4 diameter (mm)
User Cannot Edit
__Nzl5Diamete
r
= 00
0~99.9 Sets the nozzle 5 diameter (mm)
User Cannot Edit
__Nzl6Diamete
r
= 00
0~99.9 Sets the nozzle 6 diameter (mm)
User Cannot Edit
__Nzl7Diamete
r
= 00
0~99.9 Sets the nozzle 7 diameter (mm)
User Cannot Edit
__Nzl8Diamete
r
= 00
0~99.9 Sets the nozzle 8 diameter (mm)
User Cannot Edit
__Nzl9Diamete
r
= 00
0~99.9 Sets the nozzle 9 diameter (mm)
User Cannot Edit
__Nzl10Diamete
r
= 00
0~99.9 Sets the nozzle 10 diameter (mm)
User Cannot Edit
__Nzl11Diamete
r
= 00
0~99.9 Sets the nozzle 11 diameter (mm)
User Cannot Edit
__Nzl12Diamete
r
= 00
0~99.9 Sets the nozzle 12 diameter (mm)
User Cannot Edit
_______GLASS_QF_VALUE_____
_
=
__GlassQfLeadQty1 = 027
None Sets the number of leads on one side of Glass jig QFP.
User Cannot Edit
○
__GlassQfLeadWidth1 = 0 0.25
None Sets the Glass jig QFP lead width (mm).
User Cannot Edit
○
__GlassQfLeadLen1 = 0 1.5
None Sets the Glass jig QFP lead length (mm).
User Cannot Edit
○
__GlassQfPitch1 = 0 0.5
None Sets the Glass jig QFP lead pitch (mm).
User Cannot Edit
○
__GlassQfDistance1 = 019
None Sets the distance to one side of Glass jig QFP (mm).
User Cannot Edit
○
__GlassCircleDiameter1 = 02
None Sets the Glass jig QFP circle mark diameter (mm).
User Cannot Edit
○
__GlassCircleDistance1 = 0 12.94
None Sets the Glass jig QFP circle mark distance (mm).
User Cannot Edit
○
__GlassCentCircleDiameter1 = 0 5.05
None Sets the Glass jig QFP center circle diameter (mm).
User Cannot Edit
○
__GlassQfLeadQty2 = 00
None Sets the number of leads on one side of Glass jig QFP.
User Cannot Edit
○
__GlassQfLeadWidth2 = 00
None Sets the Glass jig QFP lead width (mm).
User Cannot Edit
○
__GlassQfLeadLen2 = 00
None Sets the Glass jig QFP lead length (mm).
User Cannot Edit
○
__GlassQfPitch2 = 00
None Sets the Glass jig QFP lead pitch (mm).
User Cannot Edit
○
__GlassQfDistance2 = 00
None Sets the distance to one side of Glass jig QFP (mm).
User Cannot Edit
○
__GlassCircleDiameter2 = 00
None Sets the Glass jig QFP circle mark diameter (mm).
User Cannot Edit
○
__GlassCircleDistance2 = 00
None Sets the Glass jig QFP circle mark distance (mm).
User Cannot Edit
○
__GlassCentCircleDiameter2 = 00
None Sets the Glass jig QFP center circle diameter (mm).
User Cannot Edit
○
__GlassLogicalLevel = 0 -1500
None
S
e
t
s
th
e
l
og
i
ca
l
b
r
i
g
ht
ness
diff
erence
(
-
25500
t
o
25500)
a
t
g
l
ass
ji
g
QFP
v
i
s
i
on process
i
ng.
Vi
s
i
on
processing disabled if "0".
User Cannot Edit
○
_______MATRIX_TABLE_______
_
=
__MtxTblPitch = 77
None Mark pitch (mm)
User Cannot Edit
__MtxTbl
X
= 65 65
None X-direction measure quantity
User Cannot Edit
__MtxTbl
Y
= 45 45
None Y-direction measure quantity
User Cannot Edit
__MtxTblEleganc
e
= 0.1 0.1
None Elegance (acceleration rate) value.
User Cannot Edit
__MtxTblWaitTime1 = 30 30
None The amount of time (msec) the servos wait upon completion of a movement.
User Cannot Edit
__MtxTblWaitTime2 = 150 150
None The amount of time (msec) the lamp waits before lighting.
User Cannot Edit
________NOZZLE_TYPE_______
_
=
__Nzl1Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl2Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl3Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl4Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl5Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl6Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl7Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl8Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl9Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl10Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl11Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl12Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
_______PICKUP_OFFSET______
_
=
Z_Nzl1PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl2PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl3PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl4PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl5PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl6PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl7PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl8PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
9/12
XP Type-Ⅱ Proper Data List vol.3

XP Proper Data ListType-II vol.3
Issue Date:2003/6/17
Item XP142
X
P242 Input Rang
e
Explanation
Editing
Reboot
Z_Nzl9PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl10PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl11PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl12PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
______BLACK_MASK_LEVEL_____ =
__BMLReturnRatio = 100 100
0
以上
Wh
en
bl
ac
k
mas
k
i
s app
li
e
d
,
thi
s se
t
s
th
e
b
r
i
g
ht
ness va
l
ue
(%)
th
a
t
i
s use
d
w
h
en
th
e
b
r
i
g
ht
ness
d
rops
User Cannot Edit
__BMLSide1Nzl1 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide1Nzl2 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide1Nzl3 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide1Nzl4 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide1Nzl
5
= 00
0
~
255
.
000
S
pec
ifi
es
th
e
bl
ac
k
mas
k
l
eve
l
f
or eac
h
nozz
l
e.
Calibration Data
__BMLSide1Nzl6 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide1Nzl7 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide1Nzl8 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide1Nzl9 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide1Nzl1
0
= 00
0
~
255
.
000
S
pec
ifi
es
th
e
bl
ac
k
mas
k
l
eve
l
f
or eac
h
nozz
l
e.
Calibration Data
__BMLSide1Nzl11 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide1Nzl12 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide1Nzl1B = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide1Nzl4B = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide1Nzl7B = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide1Nzl10B = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide2Nzl1 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide2Nzl2 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide2Nzl
3
= 00
0
~
255
.
000
S
pec
ifi
es
th
e
bl
ac
k
mas
k
l
eve
l
f
or eac
h
nozz
l
e.
Calibration Data
__BMLSide2Nzl4 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide2Nzl5 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide2Nzl6 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide2Nzl7 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide2Nzl
8
= 00
0
~
255
.
000
S
pec
ifi
es
th
e
bl
ac
k
mas
k
l
eve
l
f
or eac
h
nozz
l
e.
Calibration Data
__BMLSide2Nzl9 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide2Nzl10 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide2Nzl11 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide2Nzl12 = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide2Nzl1B = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
10/12
XP Type-Ⅱ Proper Data List vol.3

XP Proper Data ListType-II vol.3
Issue Date:2003/6/17
Item XP142
X
P242 Input Rang
e
Explanation
Editing
Reboot
__BMLSide2Nzl4B = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide2Nzl7B = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__BMLSide2Nzl10B = 00
0
~
255
.
000
0 Specifies the black mask level for each nozzle.
Calibration Data
__________OTHERS__________
_
=
X_MeasureFidMark = 117.5 137.1
None Sets the "Measure fiducial mark" X-coordinate (mm).
Calibration Data
Y_MeasureFidMark = 209.05 207.75
None Sets the "Measure fiducial mark" Y-coordinate (mm).
Calibration Data
X_MeasureFidMark2 = 460.5 480.1
None Sets the "Measure fiducial mark 2" X-coordinate (mm).
Calibration Data
Y_MeasureFidMark2 = 209.05 207.75
None Sets the "Measure fiducial mark 2" Y-coordinate (mm).
Calibration Data
X_MeasureFidMark3 = 117.5 137.1
None Sets the "Measure fiducial mark 3" X-coordinate (mm).
Calibration Data
Y_MeasureFidMark3 = 616.55 626.75
None Sets the "Measure fiducial mark 3" Y-coordinate (mm).
Calibration Data
__ConvWidthMtrSpeed = 0.008 0.008
None Sets the conveyor speed (mm/sec).
Calibration Data
__ConvWidthOffset = 00
None Sets the conveyor width offset at conveyor width adjustment (mm).
Calibration Data
__ConvWidthMarkDiffX = 0 -4.4
None Sets the X-direction deviation (toward secondary rail mark) from reference mark (mm).
Calibration Data
__ConvMainArrvStopDis = 20 20
More than 0 Sets the distance from the main conveyor arrival sensor to the stopper.
User Can Edit
__DLLRatio = 00
More than 0 Sets the automatically measured DLL ratio (if "0", a setting of "0.63" is adopted).
User Cannot Edit
__VT231LLRatio = 00
0, 0.7~2.0 Individual settings (%) for vision type 231 (white BGA) on the XP-242E.
User Cannot Edit
X_CoplanarityPos
X
= 00
None Sets the coplanarity check position X.
User Cannot Edit
Y_CoplanarityPos
Y
= 00
None Sets the coplanarity check position Y.
User Cannot Edit
Z_CoplanarityPos
Z
= 00
None Sets the coplanarity check position Z.
User Cannot Edit
__CoplaCamShutterSpeed = 00
More than 0 Sert the shutter speed for the coplanarity camera. The switch on the camera must be changed
User Cannot Edit
__MarkAreaTolerance = 00
0~10.00
S
e
t
s
th
e perm
i
ssa
bl
e
fid
uc
i
a
l
mar
k
rea
di
ng range
(
mm
)
.
U
se
d
w
h
en
th
e
F
-mar
k
rea
di
ng
t
o
l
erance range
is not specified in the production program.
User Can Edit
__MarkPitchTolerance = 00
0~10.00
S
e
t
s
th
e perm
i
ssa
bl
e
fid
uc
i
a
l
mar
k
rea
di
ng p
it
c
h
(
mm
)
.
U
se
d
w
h
en
th
e
F
-mar
k
rea
di
ng
t
o
l
erance range
i
s
not specified in the production program.
User Can Edit
__DesEndDistanceFromDownEnd = 00
None Not used
User Cannot Edit
__PickPosMeasureOfstX1 = 00
None
S
e
t
th
e
diff
erence
(
µm
)
b
e
t
ween
th
e p
i
c
k
up compensa
ti
on va
l
ue
f
rom
th
e mar
k
camera an
d
th
e ac
t
ua
l
p
i
c
k-
up position measurement function..
User Can Edit
__PickPosMeasureOfstY1 = 00
None
S
e
t
th
e
diff
erence
(
µm
)
b
e
t
ween
th
e p
i
c
k
up compensa
ti
on va
l
ue
f
rom
th
e mar
k
camera an
d
th
e ac
t
ua
l
p
i
c
k-
up position measurement function..
User Can Edit
__PickPosMeasureOfstX2 = 00
None
S
e
t
th
e
diff
erence
(
µm
)
b
e
t
ween
th
e p
i
c
k
up compensa
ti
on va
l
ue
f
rom
th
e mar
k
camera an
d
th
e ac
t
ua
l
p
i
c
k-
up position measurement function..
User Can Edit
__PickPosMeasureOfstY2 = 00
None
S
e
t
th
e
diff
erence
(
µm
)
b
e
t
ween
th
e p
i
c
k
up compensa
ti
on va
l
ue
f
rom
th
e mar
k
camera an
d
th
e ac
t
ua
l
p
i
c
k-
up position measurement function..
User Can Edit
__NzlSizeChkSpee
d
= 050
More than 0 Specifies the movement speed (mm/sec) when performing a nozzle size check measurement with sensor.
User Cannot Edit
__NzlSizeChkLength = 05
More than 0
S
pec
ifi
es
th
e movemen
t
di
s
t
ance
(
mm
/
sec
)
w
h
en per
f
orm
i
ng a nozz
l
e s
i
ze c
h
ec
k
measuremen
t
w
ith
sensor.
User Cannot Edit
__NzlSizeChkHeight = 020
More than 0
S
pec
ifi
es
th
e c
h
ange
i
n
h
e
i
g
ht
(
mm
)
w
h
en
i
n
iti
a
ti
ng
th
e measuremen
t
pos
iti
on
f
or a nozz
l
e s
i
ze c
h
ec
k
measurement with sensor.
User Cannot Edit
__NzlSizeChkDept
h
= 0 0.6
More than 0 Specifies the lowering distance (mm) when performing a nozzle size check measurement with sensor.
User Cannot Edit
__NzlSizeChkPosX = 00
None
S
pec
ifi
es
th
e
X
-coor
di
na
t
es o
f
th
e measuremen
t
pos
iti
on w
h
en per
f
orm
i
ng a nozz
l
e s
i
ze c
h
ec
k
measurement with sensor.
Calibration Data
__NzlSizeChkPosY = 00
None
S
pec
ifi
es
th
e
Y
-coor
di
na
t
es o
f
th
e measuremen
t
pos
iti
on w
h
en per
f
orm
i
ng a nozz
l
e s
i
ze c
h
ec
k
measurement with sensor.
Calibration Data
__NzlSizeChkPosZ = 00
None
S
pec
ifi
es
th
e
Z
-coor
di
na
t
es o
f
th
e measuremen
t
pos
iti
on w
h
en per
f
orm
i
ng a nozz
l
e s
i
ze c
h
ec
k
measurement with sensor.
Calibration Data
__MechaChuckClampTime
r
= 0 100
0~1000 Set the closing wait timer (ms) for mechanical chucks on the XP-242E.
User Can Edit
__MechaChuckUnclampTime
r
= 0 100
0~1000 Set the opening wait timer (ms) for mechanical chucks on the XP-242E.
User Can Edit
__MechaChuckSafeguard = 01
0~2 Specify settings for parts return check when using mechanical chuck.
User Cannot Edit
○
__MechaChuckMarkDiameter = 0 1.2
0, 1.2
S
pec
ifi
es
th
e mar
k
di
ame
t
er w
h
en us
i
ng par
t
s re
t
urn c
h
ec
k
.
Wh
en _
M
ec
h
a
Ch
uc
kS
a
f
e
G
uar
d
i
s se
t
t
o
1
,
ensure that the diameter is set to 1.2 (mm).
User Cannot Edit
○
__FiducialLampSetting = 00
0~1 0:Usual setting, 1:When center light source is not used.
User Can Edit
__MinimumConveyorWidth = 00
0~49.99
Thi
s se
tti
ng
i
s on
l
y
f
or cus
t
om mac
hi
nes
f
or pane
l
s
50
mm or
l
ess
i
n
th
e
Y
-
di
rec
ti
on.
(E
n
t
ry
i
s on
l
y poss
ibl
e
on modified machines).
User Cannot Edit
__MinimumPanelSize
X
= 00
0~79.99
基板
サ
イズ
X80mm
未満対応
User Can Edit
________NOZZLE_NAME________
_
=
__NzlName1 =
0
~
15
characters "Custom nozzle name" input position for nozzle 1.
User Cannot Edit
11/12
XP Type-Ⅱ Proper Data List vol.3