FK-9F98-34 XP T ype II Series T raining T ext for Service Engineers Edition 2.0 XP142E – Chapter 6 Proper Dat a Measurement s Page 15 of 30 6.1 1 Mark Camera Resolution Measurement 1. Equipment: mark camera resolution me…

FK-9F98-34 XP Type II Series Training Text for Service Engineers
Edition 2.0 XP142E – Chapter 6 Proper Data Measurements Page 14 of 30
6.9 Mark Camera Focus
1. Equipment: plate jig (AJPJ – 0060).
2. Clamp the plate jig in the main conveyor.
3. Select [Maintenance A] – [Jog] – [Fiducial] – the light comes ON for the mark camera and
the live image is displayed on the screen.
4. Inch the mark camera over the plate jig and set the focus by loosening the 4 mark
camera bracket height adjusting bolts (see photo below), and then sliding the camera up
and down until the optimum focus height is found.
4
3
2
1
5. Finally lock the mark camera bracket height adjusting bolts.
6.10 Mark Camera Brightness
1. Clamp the plate jig in the main conveyor.
2. Place the color sample on top of the plate jig.
3. Select [Maintenance A] – [Jog] – [Fiducial] – the light comes ON for the mark camera and
the live image is displayed on the screen.
4. Inch the mark camera above the color sample disc and touch the image on the screen. A
brightness value will appear.
5. Set the brightness value to 130 +/- 10 by turning the gain adjusting screw on top of the
mark camera.
6. The brightness value will vary slightly at different points on the color sample image,
therefore set the average value to 130.
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
6 – 14 CS Section

FK-9F98-34 XP Type II Series Training Text for Service Engineers
Edition 2.0 XP142E – Chapter 6 Proper Data Measurements Page 15 of 30
6.11 Mark Camera Resolution Measurement
1. Equipment: mark camera resolution measurement jig (Z3502DEAJ0020).
2. Clamp the resolution jig in the main conveyor. It should be flush with the reference rail,
and the printed surface should be uppermost.
3. Select [Maintenance C] – [Custom Maintenance] – [Fiducial] – the fiducial lamp comes
ON and the mark camera live image is displayed on the screen.
4. Inch the mark camera over the center of the resolution jig.
5. Select the cross hairs and set the center of the cross hairs in the center of the resolution
jig center dot.
6. Select [Close] to exit Maintenance Mode and then select [Maintenance A] – [Scale
Setting] and choose [Fiducial] from the drop down list. Select “1.0 [mm] pitch WHITE”
from the [CalibSet] drop down list.
7. Select [Calibration] and answer YES to the question “Set Center?” and the resolution
measurement will proceed.
8. Answer NO to the question “Do you save calibration data to FD?”
9. To the next question “Save Calibration Data?” answer YES.
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
6 – 15 CS Section

FK-9F98-34 XP Type II Series Training Text for Service Engineers
Edition 2.0 XP142E – Chapter 6 Proper Data Measurements Page 16 of 30
10. Confirm that the resolution results are within the tolerances shown below:
Mark camera resolution tolerance
X_Unit
0.0140 ~ 0.0147
X_View
8.90 ~ 9.50
Y_Unit
0.0140~ 0.0147
Y_View
6.56 ~ 6.95
11. The resolution measurement is now complete, press [OK] to return to the [Maintenance
A] screen.
6.12 Mark Positions and Angle Measurement
1. Select [Maintenance A] – [Jog] – [Fiducial] – the fiducial lamp comes ON and the mark
camera live image is displayed on the screen.
2. Select the cross hairs and then center the mark camera in the center of the parts gage
station left hand fiducial mark
{.
{
|
}
3. Select [Maintenance C] – [Mark Camera Measurement] – [F MarkPos Measure] –
[START] to measure the position of the fiducial mark. The following dialogue box will
then display:
4. Select [Change mark position] – [Execute] and the results of the measurement will be
automatically saved in [Proper Data Editor] – [OTHERS] – [X_MeasureFidMark] and
[Y_MeasureFidMark].
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
6 – 16 CS Section