FK-9F98-34 XP T ype II Series T raining T ext for Service Engineers Edition 2.0 XP242E – Chapter 5 Peripheral Adjustm ents Page 3 of 16 X Direction Static Accuracy Check 1. Clamp the reference MFU used in previous steps …

100%1 / 248
FK-9F98-34 XP Type II Series Training Text for Service Engineers
Edition 2.0 XP242E – Chapter 5 Peripheral Adjustments Page 2 of 16
4. Use a dial gage to measure the device surface A and B. Please refer to the diagram
below:
A
Tolerance: 0.05 mm / 800mm
D40
D1
0
B
5. Measure any additional MFUs in the same manner.
6. After measuring all of the MFUs, check the static accuracy of the MFUs at the clamping
position.
7. Choose one device as the reference MFU, and clamp the MFU to side 1.
8. Mount the device jig in slot No.2. Use an extension bar to attach the dial gage to the
placement head. Put the tip of the dial gage to the device jig in the Z and Y directions.
Please refer to the illustration:
Y-direction
Z-direction
Tolerance: within 0.050mm
9. Set the dial to 0.
Jog the head in the X-direction so that the dial gage tip leaves the jig.
Record the present Y-axis servo count, and then unclamp the MFU.
10. Clamp the other MFU.
11. After clamping the MFU, mount the device jig in slot No.2 and turn the servo ON. Jog the
X-axis and check the difference between the position of the two MFUs in the Y and Z
directions.
12. Repeat the procedure for any other MFUs.
Fuji Machine Mfg. Co., Ltd. Okazaki.
SMT Equipment Quality Assurance Dept.
5 – 2 CS Section
FK-9F98-34 XP Type II Series Training Text for Service Engineers
Edition 2.0 XP242E – Chapter 5 Peripheral Adjustments Page 3 of 16
X Direction Static Accuracy Check
1. Clamp the reference MFU used in previous steps to side 1.
2. Mount the device jig to device No.2 and set the dial gauge tip to the X-direction.
3. Set the dial to 0. Jog in the Y-direction to detach the dial gage tip from the jig. Record the
present X-axis servo counter. Unclamp the MFU.
4. Clamp another MFU, then mount the device jig to device No.2 and turn the servo ON. Jog
the X axis and check the difference in the X-direction.
X-direction
Tolerance: within 0.050mm
5. Repeat the procedure for any other MFUs
Device I/O Port Check
1. Load the device I/O check feeder on the device table, and use direct I/O (Y040
PartsSendD1) and (Y07F PartsSendD40) to check that all the device position I/0s are
operational.
Note: Use a cloth to wipe any dirt from the MFU connectors.
Fuji Machine Mfg. Co., Ltd. Okazaki.
SMT Equipment Quality Assurance Dept.
5 – 3 CS Section
FK-9F98-34 XP Type II Series Training Text for Service Engineers
Edition 2.0 XP242E – Chapter 5 Peripheral Adjustments Page 4 of 16
5.2 Tape Leaf Check Sensors
Double detection type tape leaf sensors
Initial Setting
1. Fix the attachment to the fiber sensor using Loctite 222 adhesive.
A
pply Loctite 222 here
Fiber sensor
A
ttachment
Amplifier Frequency Setting
DO LO
RUN
SET
Digital Display
Operation Light
Mode Lights
Mode Display
Dial Switch
L-ON/D-ON Changeover Switch