XP Type II 工程师培训手册 (2.0).pdf.pdf - 第244页
XP Proper Data ListType-II vol.3 Issue Date:2003/6/17 Item XP142 X P242 Input Rang e Explanation Editing Reboot X_Disposal1 = 346.5 351.5 None S e t s th e X -coor di na t e pos iti on f or di scar di ng sma ll s i ze re…

XP Proper Data ListType-II vol.3
Issue Date:2003/6/17
Item XP142
X
P242 Input Rang
e
Explanation
Editing
Reboot
__Camera1LeanRatio
X
= 00
None Sets the vertical angle of front camera 1.
Calibration Data
__Camera1LeanRatio
Y
= 00
None Sets the vertical angle of front camera 1.
Calibration Data
__Camera2LeanRatio
X
= 00
None Sets the vertical angle of front camera 2.
Calibration Data
__Camera2LeanRatio
Y
= 00
None Sets the vertical angle of front camera 2.
Calibration Data
_______MACHINE_ORIGIN_____
_
=
X_Stage1org = 412.1 436.5
None Sets the stage 1 origin X (mm)
Calibration Data
Y_Stage1org = 87
None Sets the stage 1 origin Y (mm)
Calibration Data
X_Stage2org = 422.9 557.5
None Sets the stage 2 origin X (mm)
Calibration Data
Y_Stage2org = 805 842
None Sets the stage 2 origin Y (mm)
Calibration Data
X_Stage3org = 00
None Sets the stage 3 origin X (mm)
User Cannot Edit
Y_Stage3org = 00
None Sets the stage 3 origin Y (mm)
User Cannot Edit
X_Stage4org = 00
None Sets the stage 4 origin X (mm)
User Cannot Edit
Y_Stage4org = 00
None Sets the stage 4 origin Y (mm)
User Cannot Edit
Z_Stage1Surface = 0.7 14.3
None Sets the stage 1 origin (height) (mm)
Calibration Data
Z_Stage2Surface = 0.7 0.8
None Sets the stage 2 origin (height) (mm)
Calibration Data
Z_Stage3Surface = 00
None Sets the stage 3 origin (height) (mm)
User Cannot Edit
Z_Stage4Surface = 00
None Sets the stage 4 origin (height) (mm)
User Cannot Edit
__DevPitch1 = 16 20
None Specifies the device pitch (Stage 1). 16:16mm pitch, 20:20mm pitch.
User Cannot Edit
__DevPitch2 = 16 20
None Specifies the device pitch (Stage 2). 16:16mm pitch, 20:20mm pitch.
User Cannot Edit
__DevPitch3 = 00
None Specifies the device pitch (Stage 3). 16:16mm pitch, 20:20mm pitch.
User Cannot Edit
__DevPitch4 = 00
None Specifies the device pitch (Stage 4). 16:16mm pitch, 20:20mm pitch.
User Cannot Edit
X_BoardOrg = 466.5 471.5
None Sets the panel origin X (counter value)
Calibration Data
Y_BoardOrg = 236.25 242.3
None Sets the panel origin Y (counter value)
Calibration Data
Z_BoardSurface = 0.7 1
None Sets the panel surface height (counter value)
Calibration Data
X_TableOrg = 550
None Specifies the X-axis counter value at head retract position. 5:5mm, 50:50mm
User Cannot Edit
Y_TableOrg = 400 350
None Specifies the Y-axis counter value at head retract position. 350:350mm, 400:400mm
User Cannot Edit
F_UpPoin
t
= 00
None Set F-axis UP limit (counter value)
Calibration Data
F_DownPoin
t
= -8.5 0
None Set F-axis DOWN limit (counter value)
Calibration Data
G_UpPoint = 00
None Set G-axis UP limit (counter value)
Calibration Data
G_DownPoin
t
= -8.5 0
None Set G-axis DOWN limit (counter value)
Calibration Data
R_Pos1 = 00
None Sets the revolver angle when nozzle 1 is at pickup position.
User Cannot Edit
Q_PosPick1 = 6.5 0
None Sets the Q-axis pickup angle when nozzle 1 is at the pickup position.
User Cannot Edit
Q_PosPlace1 = 00
None Sets the Q-axis placing position when nozzle 1 is at "R_POS1" position.
User Cannot Edit
Z_DoubleMotionPoin
t
7.5 0
None Z-axis double motion placement stopping height (mm)
Calibration Data
______NOZZLE_POSITION_____
_
=
X_NzlPosX1 = 085
None Sets the nozzle position (1) X (mm)
Calibration Data
Y_NzlPosY1 = 0 789.5
None Sets the nozzle position (1) Y (mm)
Calibration Data
Z_NzlPosZ1 = 0 0.7
None Sets the nozzle position (1) Z (mm)
Calibration Data
Z_NzlPosZH = 15.6 52
None Sets the maximum height when picking up nozzle.
Calibration Data
X_RemoverPos = 0 110
None Sets the X-coordinate of remover for tray unloading (mm).
Calibration Data
Y_RemoverPos = 0 1093
None Sets the Y-coordinate of remover for tray unloading (mm).
Calibration Data
Z_RemoverPos = 00
None Sets the Z-coordinate of remover for tray unloading (mm).
Calibration Data
__NzlPosOffsetX1 = 00
None Sets the nozzle center position offset X (1).
Calibration Data
__NzlPosOffsetY1 = 00
None Sets the nozzle center position offset Y (1).
Calibration Data
__NzlPosOffsetX2 = 00
None Sets the nozzle center position offset X (2).
Calibration Data
__NzlPosOffsetY2 = 00
None Sets the nozzle center position offset Y (2).
Calibration Data
__NzlPosOffsetX3 = 00
None Sets the nozzle center position offset X (3).
Calibration Data
__NzlPosOffsetY3 = 00
None Sets the nozzle center position offset Y (3).
Calibration Data
__NzlPosOffsetX4 = 00
None Sets the nozzle center position offset X (4).
Calibration Data
__NzlPosOffsetY4 = 00
None Sets the nozzle center position offset Y (4).
Calibration Data
__NzlPosOffsetX
5
= 00
None Sets the nozzle center position offset X (5).
Calibration Data
__NzlPosOffsetY
5
= 00
None Sets the nozzle center position offset Y (5).
Calibration Data
__NzlPosOffsetX6 = 00
None Sets the nozzle center position offset X (6).
Calibration Data
__NzlPosOffsetY6 = 00
None Sets the nozzle center position offset Y (6).
Calibration Data
__NzlPosOffsetX7 = 00
None Sets the nozzle center position offset X (7).
Calibration Data
__NzlPosOffsetY7 = 00
None Sets the nozzle center position offset Y (7).
Calibration Data
__NzlPosOffsetX
8
= 00
None Sets the nozzle center position offset X (8).
Calibration Data
__NzlPosOffsetY
8
= 00
None Sets the nozzle center position offset Y (8).
Calibration Data
__NzlPosOffsetX
9
= 00
None Sets the nozzle center position offset X (9).
Calibration Data
__NzlPosOffsetY
9
= 00
None Sets the nozzle center position offset Y (9).
Calibration Data
______DISPOSE_POSITION____
_
=
7/12
XP Type-Ⅱ Proper Data List vol.3

XP Proper Data ListType-II vol.3
Issue Date:2003/6/17
Item XP142
X
P242 Input Rang
e
Explanation
Editing
Reboot
X_Disposal1 = 346.5 351.5
None
S
e
t
s
th
e
X
-coor
di
na
t
e pos
iti
on
f
or
di
scar
di
ng sma
ll
s
i
ze re
j
ec
t
par
t
s
i
n
th
e re
j
ec
t
b
ox
(
mar
k
camera
reference).
Calibration Data
X_Disposal2 = 00
None Not used
Calibration Data
Y_Disposal1 = 202.4 206
None
S
e
t
s
th
e
Y
-coor
di
na
t
e pos
iti
on
f
or
di
scar
di
ng sma
ll
s
i
ze re
j
ec
t
par
t
s
i
n
th
e re
j
ec
t
b
ox
(
mar
k
camera
reference).
Calibration Data
Y_Disposal2 = 00
None Not used
Calibration Data
Z_Disposal2 = 01
None Sets the Z-coordinate position for discarding large size reject parts in the reject box.
Calibration Data
_______PRIZM_POSITION_____
_
=
__PrismFront = 136.5 147
None Sets the side 1 camera's image acquisition position (mm)
Calibration Data
__PrismBack = 676.5 687
None Sets the side 2 camera's image acquisition position (mm)
Calibration Data
________JIG_POSITION______
_
=
X_JigPickPos1 = 127.5 157.1
None Sets the XP-142E jig's (large) X-coordinate pickup position, XP242E jig's X-coordinate pickup position.
Calibration Data
X_JigPickPos2 = 137.5 0
None Sets the XP-142E jig's (medium) X-coordinate pickup position.
Calibration Data
X_JigPickPos3 = 147.5 0
None Sets the XP-142E jig's (small) X-coordinate pickup position.
Calibration Data
Y_JigPickPos = 209.05 207.75
None Sets the jig's Y-coordinate pickup position.
Calibration Data
Z_JigPickPos = 0.7 3.5
None Sets the jig's Z-coordinate pickup height.
Calibration Data
_________ELEGANCE_________
_
=
__PlaceEleganceQ = 00
0~1.00
S
e
t
s
th
e
Q
-ax
i
s acce
l
era
ti
on
(0
.
01
t
o
1)
a
t
XP
-
242E
p
l
acemen
t
opera
ti
on.
Wh
en se
t
t
o
"0"
, a se
tti
ng o
f
1
.
0
is adopted.
User Cannot Edit
__PlaceUpSpeedRati
o
= 0.05 0.05
0~1.00 XP-242E speed coefficient for UP motion after placement. (Applies only for Vision Types 100 and 20).
User Can Edit
__PlaceUpMaxSpeed = 1500 1500
<TypeI>
0~1000.0
<TypeII>
0~1500.0 Maximum speed reference for Z-axis speed after part placement.
User Can Edit
__CycleStealEleganc
e
= 11
0.01~1.00 Set the elegance value for the cycle steal after the time set at "_CycleStealTime" elapses.
User Can Edit
__MainteMaxVRatio = 0.1 0.1
0.01~1.00 Specifies the speed ration when in maintenance mode.
User Cannot Edit
_______F_GLASS_VALUE______
_
=
XMainStDecelPo
s
= 00
None Panel deceleration point (X-axis).
User Cannot Edit
YMainStDecelPo
s
= 00
None Panel deceleration point (Y-axis).
User Cannot Edit
XMainStArrivPos = 00
None Panel arrival point (X-axis).
User Cannot Edit
YMainStArrivPos = 00
None Panel arrival point (Y-axis).
User Cannot Edit
___________TRAY___________
_
=
T_TrayOrg = 0 465
None Sets the T-axis position (shuttle advance enabled position) fror tray position 101.
Calibration Data
T_TrayEmptyOrg = 0 495
None Sets the T-axis position where a "no tray at tray position 101" judgement is made.
Calibration Data
U_ShuttleBackwardOfs
t
= 00
None Sets the shuttle retract limit offset (mm).
Calibration Data
U_ShuttleForwardOfs
t
= 00
None Sets the shuttle advance limit offset (mm).
Calibration Data
U_ShuttleClampPo
s
= 0 526
None Sets the shuttle clamp position (mm).
Calibration Data
__ShuttleClampOfst = 00
-
1.5000~1.5
000
Set the offset (mm) for the clamp stroke of the tray shuttle. This setting is only valid for machines with
upgraded tray units (when "_TrayUnitType" has been set to "1").
Calibration Data
__ElevotorOfst2 = 00
None Sets the T-axis position offset (mm) when a 11* tray can be extended.
Calibration Data
__ElevotorOfst3 = 00
None Sets the T-axis position offset (mm) when a 12* tray can be extended.
Calibration Data
__ElevotorOfst4 = 00
None Sets the T-axis position offset (mm) when a 13* tray can be extended.
Calibration Data
__ElevotorOfst5 = 00
None Sets the T-axis position offset (mm) when a 14* tray can be extended.
Calibration Data
__ElevotorOfst6 = 00
None Sets the T-axis position offset (mm) when a 15* tray can be extended.
Calibration Data
__ElevotorOfst7 = 00
None Sets the T-axis position offset (mm) when a 16* tray can be extended.
Calibration Data
__ElevotorOfst8 = 00
None Sets the T-axis position offset (mm) when a 17* tray can be extended.
Calibration Data
__ElevotorOfst9 = 00
None Sets the T-axis position offset (mm) when a 18* tray can be extended.
Calibration Data
__ElevotorOfst10 = 00
None Sets the T-axis position offset (mm) when a 19* tray can be extended.
Calibration Data
__TrayPickUpOfstZ = 00
-
3.0000~3.0
000
Set the offset (mm) for the pickup height of tray parts. However, no offset is performed if this value is set
below -0.3 or above +0.3.
User Can Edit
________PLACE_OFFSET______
_
=
__PlaceGlobalOfst
X
= 00
None Sets the placement global offset X (valid only for Vision Types 10, 18, 20).
User Cannot Edit
__PlaceGlobalOfst
Y
= 00
None Sets the placement global offset Y (valid only for Vision Types 10, 18, 20).
User Cannot Edit
__PlaceGlobalOfst
Q
= 00
None Sets the placement global offset Q (valid only for Vision Types 10, 18, 20).
User Cannot Edit
__PlaceGlobalOfstX
R
= 00
None Sets the placement global offset X (valid only for Vision Types 10, 18, 20).
User Cannot Edit
__PlaceGlobalOfstY
R
= 00
None Sets the placement global offset Y (valid only for Vision Types 10, 18, 20).
User Cannot Edit
__PlaceGlobalOfstQ
R
= 00
None Sets the placement global offset Q (valid only for Vision Types 10, 18, 20).
User Cannot Edit
__PlaceOfstForFidCamAng
X
= 00
None Sets the placement global offset X (mm).
User Cannot Edit
__PlaceOfstForFidCamAng
Y
= 00
None Sets the placement global offset Y (mm).
User Cannot Edit
8/12
XP Type-Ⅱ Proper Data List vol.3

XP Proper Data ListType-II vol.3
Issue Date:2003/6/17
Item XP142
X
P242 Input Rang
e
Explanation
Editing
Reboot
______NOZZLE_DIAMETER_____
_
=
__Nzl1Diamete
r
= 00
0~99.9 Sets the nozzle 1 diameter (mm)
User Cannot Edit
__Nzl2Diamete
r
= 00
0~99.9 Sets the nozzle 2 diameter (mm)
User Cannot Edit
__Nzl3Diamete
r
= 00
0~99.9 Sets the nozzle 3 diameter (mm)
User Cannot Edit
__Nzl4Diamete
r
= 00
0~99.9 Sets the nozzle 4 diameter (mm)
User Cannot Edit
__Nzl5Diamete
r
= 00
0~99.9 Sets the nozzle 5 diameter (mm)
User Cannot Edit
__Nzl6Diamete
r
= 00
0~99.9 Sets the nozzle 6 diameter (mm)
User Cannot Edit
__Nzl7Diamete
r
= 00
0~99.9 Sets the nozzle 7 diameter (mm)
User Cannot Edit
__Nzl8Diamete
r
= 00
0~99.9 Sets the nozzle 8 diameter (mm)
User Cannot Edit
__Nzl9Diamete
r
= 00
0~99.9 Sets the nozzle 9 diameter (mm)
User Cannot Edit
__Nzl10Diamete
r
= 00
0~99.9 Sets the nozzle 10 diameter (mm)
User Cannot Edit
__Nzl11Diamete
r
= 00
0~99.9 Sets the nozzle 11 diameter (mm)
User Cannot Edit
__Nzl12Diamete
r
= 00
0~99.9 Sets the nozzle 12 diameter (mm)
User Cannot Edit
_______GLASS_QF_VALUE_____
_
=
__GlassQfLeadQty1 = 027
None Sets the number of leads on one side of Glass jig QFP.
User Cannot Edit
○
__GlassQfLeadWidth1 = 0 0.25
None Sets the Glass jig QFP lead width (mm).
User Cannot Edit
○
__GlassQfLeadLen1 = 0 1.5
None Sets the Glass jig QFP lead length (mm).
User Cannot Edit
○
__GlassQfPitch1 = 0 0.5
None Sets the Glass jig QFP lead pitch (mm).
User Cannot Edit
○
__GlassQfDistance1 = 019
None Sets the distance to one side of Glass jig QFP (mm).
User Cannot Edit
○
__GlassCircleDiameter1 = 02
None Sets the Glass jig QFP circle mark diameter (mm).
User Cannot Edit
○
__GlassCircleDistance1 = 0 12.94
None Sets the Glass jig QFP circle mark distance (mm).
User Cannot Edit
○
__GlassCentCircleDiameter1 = 0 5.05
None Sets the Glass jig QFP center circle diameter (mm).
User Cannot Edit
○
__GlassQfLeadQty2 = 00
None Sets the number of leads on one side of Glass jig QFP.
User Cannot Edit
○
__GlassQfLeadWidth2 = 00
None Sets the Glass jig QFP lead width (mm).
User Cannot Edit
○
__GlassQfLeadLen2 = 00
None Sets the Glass jig QFP lead length (mm).
User Cannot Edit
○
__GlassQfPitch2 = 00
None Sets the Glass jig QFP lead pitch (mm).
User Cannot Edit
○
__GlassQfDistance2 = 00
None Sets the distance to one side of Glass jig QFP (mm).
User Cannot Edit
○
__GlassCircleDiameter2 = 00
None Sets the Glass jig QFP circle mark diameter (mm).
User Cannot Edit
○
__GlassCircleDistance2 = 00
None Sets the Glass jig QFP circle mark distance (mm).
User Cannot Edit
○
__GlassCentCircleDiameter2 = 00
None Sets the Glass jig QFP center circle diameter (mm).
User Cannot Edit
○
__GlassLogicalLevel = 0 -1500
None
S
e
t
s
th
e
l
og
i
ca
l
b
r
i
g
ht
ness
diff
erence
(
-
25500
t
o
25500)
a
t
g
l
ass
ji
g
QFP
v
i
s
i
on process
i
ng.
Vi
s
i
on
processing disabled if "0".
User Cannot Edit
○
_______MATRIX_TABLE_______
_
=
__MtxTblPitch = 77
None Mark pitch (mm)
User Cannot Edit
__MtxTbl
X
= 65 65
None X-direction measure quantity
User Cannot Edit
__MtxTbl
Y
= 45 45
None Y-direction measure quantity
User Cannot Edit
__MtxTblEleganc
e
= 0.1 0.1
None Elegance (acceleration rate) value.
User Cannot Edit
__MtxTblWaitTime1 = 30 30
None The amount of time (msec) the servos wait upon completion of a movement.
User Cannot Edit
__MtxTblWaitTime2 = 150 150
None The amount of time (msec) the lamp waits before lighting.
User Cannot Edit
________NOZZLE_TYPE_______
_
=
__Nzl1Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl2Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl3Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl4Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl5Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl6Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl7Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl8Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl9Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl10Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl11Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
__Nzl12Typ
e
= 00
0~2 Specifies the nozzle type 0:Standard, 1:Mechanical Chuck, 2:Custom.
User Cannot Edit
_______PICKUP_OFFSET______
_
=
Z_Nzl1PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl2PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl3PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl4PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl5PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl6PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl7PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
Z_Nzl8PickUpOfs
t
= 00
None Sets the pickup offset Z (mm) for each nozzle used in XP-142E pickups.
Calibration Data
9/12
XP Type-Ⅱ Proper Data List vol.3