FK-9F98-34 XP Type II Series Training Text for Service Engineers
Edition 2.0 XP142E – Chapter 5 Peripheral Adjustments Page 2 of 14
5.2 MFU Device Table Measurement
1. Use a dial gage to measure device surfaces A and B. Please refer to the diagram below:
A
D50
D1
0
B
2. Tolerance is 0.05mm/800mm.
3. Measure the second MFU and any additional MFUs in the same manner.
Y and Z Direction Static Accuracy
1. Choose one MFU as the reference and clamp it at side 1.
2. Mount the device jig in slot No. 2 and use an extension bar to attach the two dial gages to
the placement head.
3. Put the tip of the dial gages against the end of the device jig in the Y and the Z directions.
Please refer to the following illustration:
Z-direction
Y-direction
Tolerance: ±0.035mm
4. Set the dial gages to 0 and jog the head away from the device jig in the X direction.
Record the current Y-axis counter value and then unclamp the MFU.
5. In place of the reference MFU clamp the second MFU or any additional MFUs at side 1.
6. Mount the device jig in slot No. 2 and turn the servo power ON. Ensure the Y counter
value is the same as that recorded in step 4 and then jog the head in the X direction until
the dial gages contact the device jig in the Y and Z directions.
7. Check the difference between the reference MFU and the second (or additional MFUs) in
the Z and Y directions. Tolerance is +/- 0.035mm. If out of tolerance please contact
FUJI.
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
5 – 2 CS Section

FK-9F98-34 XP Type II Series Training Text for Service Engineers
Edition 2.0 XP142E – Chapter 5 Peripheral Adjustments Page 3 of 14
X Direction Static Accuracy
1. Clamp the reference MFU used in previous steps to side 1.
2. Mount the device jig in slot No.2 and set the dial gage tip against the jig in the X direction.
Please refer to the illustration below:
X-direction
Tolerance: ±0.035mm
3. Set the dial to 0 and then jog the head in the Y direction to slide the dial gage tip away
from the jig.
4. Record the current X-axis servo counter value and then unclamp the MFU.
5. Clamp the second MFU (or any additional MFUs) and mount the device jig in slot No.2
and turn the servo ON.
6. Ensure the X axis counter value is the same as that recorded in step 4 and then jog the
head in the Y direction until the dial gage tip contacts the jig.
7. Check the difference between the reference MFU and the second MFU (or any additional
MFUs) in the X-direction. Tolerance is +/- 0.035mm.
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
5 – 3 CS Section

FK-9F98-34 XP Type II Series Training Text for Service Engineers
Edition 2.0 XP142E – Chapter 5 Peripheral Adjustments Page 4 of 14
5.3 Tape Leaf Sensors
Initial Setting
1. Fix the attachment to the fiber sensor using Loctite 222 adhesive.
Double detection type tape leaf sensors
A
pply Loctite 222 here
Fiber sensor
A
ttachment
Amplifier Frequency Setting
DOLO
RUN
SET
TMR
ADJ
Digital Display
Operation Light
Mode Lights
Mode Display
Dial Switch
L-ON/D-ON Changeover Switch
1. Set the L-ON/D-ON changeover switch to L_ON.
2. Press the dial switch once (the RUN light in the Mode Display flashes and “AA” is
displayed on the digital display).
3. Turn the dial switch until SET flashes on the “Mode Display”.
4. Press and hold the dial switch for 3 seconds (SET stops flashing and the Mode Lights
come ON).
5. Turn the dial switch until “– –“ is displayed on the digital display.
6. Press and hold the dial switch for 8 seconds.
Fuji Machine Mfg. Co., Ltd. Okazaki
SMT Equipment Quality Assurance Dept.
5 – 4 CS Section