XP Type II 工程师培训手册 (2.0).pdf.pdf - 第177页
FK-9F98-34 XP T ype II Series T raining T ext for Service Engineers Edition 2.0 XP242E – Chapter 6 Proper Data Mea surement s Page 22 of 30 6. Select [Maintenance C] – [Nozzle Measurement] – [Size Check Ref. Measurement]…

FK-9F98-34 XP Type II Series Training Text for Service Engineers
Edition 2.0 XP242E – Chapter 6 Proper Data Measurements Page 21 of 30
6.12 Nozzle Size Check
1. Make sure the configuration in the nozzle change station matches the setting in the
nozzle editor.
Nozzle Size Check
2. Select [Maintenance C] – [Proper Data Editor] – [OPERATION_2] and set the
following proper data:
Proper Data Name Setting
_NzSizeChkFlag 1
3. Select [Maintenance C] – [Proper Data Editor] – [OTHERS] and set the following
proper data:
Proper Data Name Setting
NzSizeChkSpeed 50.0
NzSizeChkLength 5.0
NzSizeChkHeight 20.0
NzSizeChkDepth 0.6
4. Select [Maintenance C] – [Nozzle Measurement] – [Size Check Pos. Measurement]
– [START] to carry out the measurement.
5. Once the measurement is completed, select [Maintenance C] – [Proper Data Editor]
– [OTHERS] – and check that the results of the measurement have been recorded
in “_NzSizeChkPosY” and “_NzSizeChkPosZ”.
Fuji Machine Mfg. Co., Ltd. Okazaki.
SMT Equipment Quality Assurance Dept.
6 – 21 CS Section

FK-9F98-34 XP Type II Series Training Text for Service Engineers
Edition 2.0 XP242E – Chapter 6 Proper Data Measurements Page 22 of 30
6. Select [Maintenance C] – [Nozzle Measurement] – [Size Check Ref. Measurement]
– [START] to carry out the measurement.
7. The results of the [Size Check Ref. Measurement] are saved in the hard drive: /sdo
– System – NzlSizeRange.csv.
6.13 Nozzle Station Operation
1. From the production screen select [Nozzle Editor] and configure the nozzle entries
as described in the following table:
Nozzle Number Nozzle diameter (mm)
1 0.7
2 1.0
3 1.3
4 1.8
5 2.5
6 3.7
7 10
8 15
9 20
2. Arrange the nozzles in the nozzle station so that they match the nozzle editor
configuration.
3. Select [Manual Operation] – [Nozzle operation] – [1] – [Execute] – [START] to pick
up nozzle 1. Check that the placing head picks up the nozzle smoothly and then
select [Place] – [Execute] – [START] to return the nozzle to the nozzle station.
4. Repeat this procedure for all the remaining nozzles.
6.14 Parts Reject Positions
Small Parts Reject Position
1. Select [Maintenance A] – [Jog] – [Fiducial] and display the cross hairs on the
screen.
Small parts reject pos.
12.5mm
35mm
2. Jog the fiducial camera until it is in the centre of the small parts reject box on the
fixed rail. Refer to the diagram above for the dimensions of the box.
Fuji Machine Mfg. Co., Ltd. Okazaki.
SMT Equipment Quality Assurance Dept.
6 – 22 CS Section

FK-9F98-34 XP Type II Series Training Text for Service Engineers
Edition 2.0 XP242E – Chapter 6 Proper Data Measurements Page 23 of 30
3. Select [Maintenance C] – [Proper Data Editor] – [Dispose Position] –
[X_Disposal1/Y_Disposal1] – [Direct Servo Input] to save the current X-axis and Y-
axis positions in proper data.
Large Parts Reject Position
1. Equipment: Nozzle jig (Z95314DEPJ0070)
2. Select [Maintenance A] – [I/O check] – [Y021 NozzleUnhold] – [OFF] and attach the
nozzle jig to the placing head.
3. Select [Maintenance A] – [Jog] – and carefully inch the nozzle jig above the surface
of the reject parts tray.
4. Press the emergency stop button to cut the 200 volt power supply to the servos and
then manually descend the Z-axis until the nozzle jig contacts the surface of the
reject parts tray.
5. Select [Maintenance C] – [Proper data editor] – [Dispose position] – [Z_Disposal 2]
– [Direct servo input] to save the current Z-axis position in proper data.
6. In the case of the reject parts tray the machine software determines the position of
X and Y disposal, so the “X_Disposal 2” and “Y_Disposal 2” entries should be set to
0 by default.
6.15 MFU Pick Up Position
1. Equipment: Nozzle jig (Z9531DEPJ0070). MFU pick up position measurement jig
(Z5531ADPEPJ9010).
2. Select [Manual Operation] – [MFU Clamp] to clamp the MFU to the machine.
3. Mount the MFU pick up position measurement jig at device position 25.
4. Select [Maintenance A] – [Jog] – [Fiducial] and display the cross hairs on the
screen.
5. Inch the X and Y axes until the fiducial camera cross hairs are centered on the XY
pick up position jig mark.
Z5531ADPEPJ9010
Fuji Machine Mfg. Co., Ltd. Okazaki.
SMT Equipment Quality Assurance Dept.
6 – 23 CS Section