User Manual SIPLACE CA-Series 2 Operational Safety From software version SC.708.0 Edition 12/20 14 EN -DRA FT 2.11 Energy State After Switching off Main Switch 111 2 Fig. 2.1 1 - 5 Power supply unit, view from back X100 …

100%1 / 518
2 Operational Safety User Manual SIPLACE CA-Series
2.11 Energy State After Switching off Main Switch From software version SC.708.0 Edition 12/2014 EN -DRAFT
110
2
Fig. 2.11 - 4 Power supply unit, view from front
Q1 Main switch
X102 Service socket
F1 Fuse for service socket
User Manual SIPLACE CA-Series 2 Operational Safety
From software version SC.708.0 Edition 12/2014 EN -DRAFT 2.11 Energy State After Switching off Main Switch
111
2
Fig. 2.11 - 5 Power supply unit, view from back
X100 Connection terminals for mains power supply cable
L20 Discharge inductor with fuses F21, F22 and F23
Z1 Mains filter
2 Operational Safety User Manual SIPLACE CA-Series
2.11 Energy State After Switching off Main Switch From software version SC.708.0 Edition 12/2014 EN -DRAFT
112
The following table specifies the voltages of modules when the machine is switched off at the main
switch, but still connected to the mains supply.
2
Module Voltage
Terminal panel X100
Mains filter Z1
Terminals L1, L2, L3
3 x 208 VAC
3 x 230 VAC
3 x 380 VAC
3 x 400 VAC
3 x 415 VAC
Service socket X102
120 VAC
130 VAC
220 VAC
230 VAC
240 VAC
Automatic circuit breaker F1
120 VAC
130 VAC
220 VAC
230 VAC
240 VAC
Main switch Q1
Terminals L1, L2, L3
3 x 208 VAC
3 x 230 VAC
3 x 380 VAC
3 x 400 VAC
3 x 415 VAC
Main switch Q1
Terminals T1, T2, T3
0 VAC
Power supply unit
(see item 5 of fig. 2.9 - 2
)
Test socketX11
GNDX12
Test socketX13_1
Test socketX13_4
GNDX13_7
< 10 VDC
< 10 VDC
< 10 VDC
Computer unit (see fig. 2.11 - 3
)
Test socket+ 12 VDC
Test socket- 12 VDC
Test socket+ 15 VDC
Test socket-15 VDC
Test socket+ 5 VDC
Test socket+ 52 VDC
Test socket+ 3.3 VDC
GND
0 VDC
0 VDC
0 VDC
0 VDC
0 VDC
0 VDC
0 VDC