00197498-03_UM_SiplaceCA-Serie_EN.pdf - 第462页
8 Station Extensions User manua l SIPLACE CA-Series 8.1 Nozzle Changers From software version SC.708.0 Edition 12/2014 EN -DRAFT 462 8.1.3.2 T echnical Dat a 8 8.1.3.3 Nozzle Changer "Row 2" for the SIPLACE Mul…

User manual SIPLACE CA-Series 8 Station Extensions
From software version SC.708.0 Edition 12/2014 EN -DRAFT 8.1 Nozzle Changers
461
Nozzle magazine for 28xx nozzles 8
8
Fig. 8.1 - 12 Nozzle magazine for 28xx nozzles
(1) 5 garages for 28xx nozzles with a maximum nozzle length of 12.5 mm
(garage numbers 1, 5, 6, 8 and 9)
(2) 4 garages for 28xx nozzles with a maximum nozzle length of 16.5 mm
(garage numbers 2, 3, , 4 and 7)
(3) Fiducials (only visible when locking plate open)

8 Station Extensions User manual SIPLACE CA-Series
8.1 Nozzle Changers From software version SC.708.0 Edition 12/2014 EN -DRAFT
462
8.1.3.2 Technical Data
8
8.1.3.3 Nozzle Changer "Row 2" for the SIPLACE MultiStar
The "nozzle changer for row 2" option enables you to configure an additional row of nozzle chang-
ers for the SIPLACE MultiStar.
The retrofit package contains the nozzle changer and an assembly kit.
Nozzle changer for the SIPLACE MultiStar and SIPLACE SpeedStar
Dimensions (length x width x height) 449 x 94.5 x 55 mm³
Number of nozzle holders
Type 20xx 60
Type 28xx 9
Type 10xx, 11xx, 12xx 72
Nozzle types 20xx (CPP head)
28xx (CPP head)
10xx, 11xx, 12xx (C&P20 head)
Nozzle changeover time Approx. 2s per nozzle
Compressed air connection 0.48 MPa (4.8 bar)

User manual SIPLACE CA-Series 8 Station Extensions
From software version SC.708.0 Edition 12/2014 EN -DRAFT 8.1 Nozzle Changers
463
8.1.3.4 Assembly
The nozzle changers are fixed to the COT insert.
8
Fig. 8.1 - 13 Assembly position of nozzle changer - view from below
(1) Sloping side points towards the COT insert
(2) Vertical side points towards the PCB conveyor
Align the nozzle changer so that the sloping side points towards the COT insert.
8
WARNING
Risk of head crashes with mixed configurations!
There is a risk of head crashes with mixed configurations.
Only install the associated nozzle changer for each placement head, with the nozzle
magazines for the respective placement head.