00197498-03_UM_SiplaceCA-Serie_EN.pdf - 第353页

User Manual SIPLACE CA-Series 6 Working with the Machine From software version SC.708.0 Edition 12/2014 EN -DRAFT 6.2 The User Interface 353 The following view will open: 6 Fig. 6.2 - 4 User interface in the "WPC&qu…

100%1 / 518
6 Working with the Machine User Manual SIPLACE CA-Series
6.2 The User Interface From software version SC.708.0 Edition 12/2014 EN -DRAFT
352
The following view will open:
6
Fig. 6.2 - 3 User interface in the "Feeder modules, components and nozzles" view (example of SIPLACE CA4
shown)
Legend
(1) Toolbar ("Feeder modules, components and nozzles" button)
(2) Vertical toolbar in "Feeder modules, component and nozzles" view
(3) Processing area with 4 gantries
(4) Button for SIPLACE Wafer System (SWS) at location 2
Click, for example, on the SIPLACE Wafer System (SWS) of gantry 1 (button 4), to open the
SWS functions.
(1)
(2)
(3)
(4)
User Manual SIPLACE CA-Series 6 Working with the Machine
From software version SC.708.0 Edition 12/2014 EN -DRAFT 6.2 The User Interface
353
The following view will open:
6
Fig. 6.2 - 4 User interface in the "WPC" view (example of SIPLACE SX shown)
Legend
(1) Vertical toolbar for "SIPLACE Wafer System" functions
(2) Buttons for changing directly to a different gantry
(3) "Up one level" button, to return to previous view (here: "Feeder modules, component and
nozzles" view, see previous diagram)
(1)
(2)
(3)
6 Working with the Machine User Manual SIPLACE CA-Series
6.2 The User Interface From software version SC.708.0 Edition 12/2014 EN -DRAFT
354
6.2.5 Settings
The "Settings" view allows you to change the various user settings, software options and machine
options.
Click on "Settings" in the toolbar .
The right-hand side shows an additional toolbar. The following table briefly describes the icons
and settings.
Icon Settings Description
Machine settings Only for "Advanced production", "Service customer" or "Service
SIPLACE".
Allows you to set the operating mode and options (e.g. running
options).
Allows you to shut down the machine
Allows you to change over to the operating system.
User settings Setting the operator level.
Allows you to set the language. As a default, English or German
can be selected. A language CD is provided for installation of other
languages.
Further options can be set from the "Advanced production" operator
level.
Machine options No options can be changed in the "Production" level.
Configuration of machine options.
Software options Only for "Advanced production", "Service customer" or "Service
SIPLACE".
Allows you to activate various test functions.
Overview of con-
nected external
systems
Shows all connected external systems (e.g. OIS, SetupCenter).
Shows the connection status and the memory used or deletes the
connected systems.