6 Working with the Machine User Manual SIPLACE CA-Series 6.15 Observing the Indicator Lamps for Operating State s From software version SC.708.0 Edition 12/2014 EN -DRAFT 394 unchanged flashes (7,7) unchanged Waiting for…

User Manual SIPLACE CA-Series 6 Working with the Machine
From software version SC.708.0 Edition 12/2014 EN -DRAFT 6.15 Observing the Indicator Lamps for Operating States
393
6.15.2 General Operating States
– Operating status indicator lamp L2 (green) on continuously
The placement system is in service.
– Operating status indicator lamp L2 (green) flashes
The placement system is waiting for a PCB on the input belt or the placement system is wait-
ing until the output belt is free.
– Right fault indicator lamp L1 (white) flashes
One or more tracks are empty on the right-hand side of the placement system. The placement
system continues to place any remaining components.
– Left fault indicator lamp L3 (white) flashes
One or more tracks are empty on the left-hand side of the placement system. The placement
system continues to place any remaining components.
– Right fault indicator lamp L1 (white ) on continuously - operating status lamp L2 (green) off
An error has occurred on the right-hand side of the placement system -> the placement sys-
tem has stopped.
– Left fault indicator lamp L3 (white ) on continuously - operating status lamp L2 (green) off
An error has occurred on the left-hand side of the placement system -> the placement system
has stopped.
– Both fault indicator lamps L1 and L3 (white ) on continuously - operating status lamp L2
(green) off
An error has occurred on the whole machine-> the placement machine has stopped.
6.15.3 Programmed Operating Status Displays
The following table shows the programmed operating status displays in the standard configuration
(version as supplied) and lists their meaning on the individual lamps of the main fault indicator.
The entries in the table next to "flashes" refer to the frequency with which the relevant lamp flashes
for a given event. The entry (1, 5), for example, can be explained as follows:
– The first number in the brackets indicates the time, expressed in 100 ms intervals, for which
the fault indicator lamp is switched on, i.e. 1 x 100 ms in the above example.
– The second number in the brackets indicates the time, expressed in 100 ms intervals, for
which the fault indicator lamp is switched off, i.e. 5 x 100 ms in the above example.
6
L1 (white)
(right lamp)
L2 (green) L3 (white)
(left lamp)
Meaning
Operating state
flashes (1,10) flashes (7,7) flashes (1,10) Reference run
unchanged flashes (1,5) unchanged Waiting until axes in position

6 Working with the Machine User Manual SIPLACE CA-Series
6.15 Observing the Indicator Lamps for Operating States From software version SC.708.0 Edition 12/2014 EN -DRAFT
394
unchanged flashes (7,7) unchanged Waiting for setup data
unchanged flashes (7,7) unchanged Waiting for cluster data
unchanged flashes (7,7) unchanged Load table program
unchanged flashes (7,7) unchanged Position detection
unchanged flashes
(1,10)
unchanged Bad fiducial detection
unchanged flashes (7,7) unchanged Nozzle configuration test
unchanged flashes (7,7) unchanged Feeder position detection
unchanged flashes (7,7) unchanged One track is empty
unchanged flashes (7,7) unchanged No further track available
unchanged flashes (7,7) unchanged Go to refill position
unchanged flashes (7,7) unchanged Transport being initialized
unchanged flashes (7,7) unchanged Place PCB in input conveyor
flashes (1,10) flashes (7,7) unchanged Remove PCB from output conveyor
unchanged flashes (7,7) flashes (1,10) Remove PCB from output conveyor 2
flashes (1,10) flashes (7,7) flashes (1,10) Width adjustment
unchanged flashes
(1,10)
unchanged Transport PCB
flashes (1,10) flashes (7,7) flashes (1,10) Both output conveyors are cleared
on flashes
(1,10)
on Transport error
on off on Go to service position
on Placement
flashes
(1,20)
Waiting for processing data
Error display
on off unchanged Machine error, right
on off unchanged Track empty, right
on off unchanged Nozzle configuration, right
on off unchanged Transport error, right
on off on Fiducial error, left and right
on off on Fiducial error, left and right
unchanged off on Track empty, left
unchanged off on Nozzle configuration, left
L1 (white)
(right lamp)
L2 (green) L3 (white)
(left lamp)
Meaning

User Manual SIPLACE CA-Series 6 Working with the Machine
From software version SC.708.0 Edition 12/2014 EN -DRAFT 6.15 Observing the Indicator Lamps for Operating States
395
unchanged off on Transport error, left
unchanged off on Machine error, left
Pickup error display
unchanged unchanged flashes (1,20) First track empty, left
unchanged unchanged flashes (5,20) Other tracks empty, left
unchanged unchanged flashes (5,5) Second to last track is being used
unchanged unchanged flashes (1,2) Last track is being used, left
flashes (1,20) unchanged unchanged First track empty, right
flashes (5,20) unchanged unchanged Other tracks empty, right
flashes (5,5) unchanged unchanged Second to last track is being used, right
flashes (1,2) unchanged unchanged Last track is being used, right
L1 (white)
(right lamp)
L2 (green) L3 (white)
(left lamp)
Meaning