00197498-03_UM_SiplaceCA-Serie_EN.pdf - 第333页
User Manual SIPLACE CA-Series 5 Setting up and Commissioning From software version SC.708.0 Editi on 12/2014 EN -DRAFT 5.6 Fitting the SWS 333 5 Carefully push the SWS into the p lacement mach ine, until it is approx. …

5 Setting up and Commissioning User Manual SIPLACE CA-Series
5.6 Fitting the SWS From software version SC.708.0 Edition 12/2014 EN -DRAFT
332
5.6.3.2 Moving the SWS into the Placement Machine
5
5
Fig. 5.6 - 1 Connections on the SWS
5
5
Push the fork of the fork lift truck under the SWS (see section 5.2.4.3 on page 262).
Lift the SWS and align it to the placement machine. If the lifting range of the hand lift is not
sufficient, use wooden blocks or a similar object.
PLEASE NOTE
Before inserting the SWS, make sure that the CAN Bus connection X1x5 and X1x6,
the compressed air connection and the FFI communication interface W11 on the
SWS are accessible.
(1) Manometer for compressed air supply (2) Voltage supply
(3) Communication with SIPLACE machine (4) CAN bus
(5) Compressed air connection (modified
adapter dummy connector [03011592-01])
(6) LAN1
(7) LAN2
2
1
3
4
5
6
7

User Manual SIPLACE CA-Series 5 Setting up and Commissioning
From software version SC.708.0 Edition 12/2014 EN -DRAFT 5.6 Fitting the SWS
333
5
Carefully push the SWS into the placement machine, until it is approx. 30 cm before the
bumper (see following fig.), so that you still have enough room to connect the SWS and
placement machine connections.
5
Fig. 5.6 - 2 Bumper
(1) Bumper
CAUTION
Risk of collision!
The monitor of the SWS could hit the placement machine cover when moving into the ma-
chine.
Before inserting the SWS into the machine, open the SWS monitor, so that this can
not hit the cover of the placement machine.
1

5 Setting up and Commissioning User Manual SIPLACE CA-Series
5.6 Fitting the SWS From software version SC.708.0 Edition 12/2014 EN -DRAFT
334
5.6.3.3 Connecting the SWS to the Placement Machine
The SWS connections need to be connected as follows to the placement machine:
– CAN Bus connections X1x6 and X1x5
– Compressed air connection to compressed air connection
– FFI communication interface W11 to FFI communication interface X1x3
5
Fig. 5.6 - 3 Position of the connections on the placement machine
(1) CAN Bus connection X1x5
(2) CAN Bus connection X1x6
(3) Compressed air connection (modified dummy connector [03011592-01])
(4) FFI communication connection X1x3
5
PLEASE NOTE
Connection points no longer accessible after installation
Connect the SWS to the placement machine before performing alignment and final
adjustments.
1
2
3
4