5 Setting up and Commissioning User Manual SIPLACE CA-Series 5.5 Setting Up the Placement Machine From software version SC.708.0 Edition 12/2014 EN -DR AFT 300 5.5.8.3 Fitting the Axis Unit  Carefully lift the axis unit…

100%1 / 518
User Manual SIPLACE CA-Series 5 Setting up and Commissioning
From software version SC.708.0 Edition 12/2014 EN -DRAFT 5.5 Setting Up the Placement Machine
299
5.5.8.2 Axis Unit CA4 (Gantries 2 and 3) - Connecting the Plug
Connect the power cable as shown in the following diagram:
5
5
Check the switch settings of S1
1: ON
2: ON
Axis unit CA4 plug Connection cable Please note
Plug Cable
X21 X21
03009782
03009783
03009784
03009785
03009786 W1-W5
Secure connector with clips
X22 X22
03009802
03009803
03009804
03009805
03009807
Secure connector with clips
X01_3sq X4tr 03009780 Snap connector into place
X02_3sq X4tt 03009781 Snap connector into place
X05_3sq X4ur 03009800 Snap connector into place
X06_3sq X4ut 03009801 Snap connector into place
X01_1sq
X02_1sq
X03_1sq
X1to
X3to
X5to
03009791
03009792
03009793
Insert as far as the stop
X04_1sq
X09_1sq
X10_1sq
X1tp
X3tp
X5tp
03009794
03009795
03009796
Insert as far as the stop
X05_1sq
X06_1sq
X07_1sq
X1uo
X3uo
X5uo
03009811
03009812
03009813
Insert as far as the stop
X08_1sq
X11_1sq
X12_1sq
X1up
X3up
X5up
03009814
03009815
03009816
Insert as far as the stop
X30_1sq
X30_2sq
X30_1sq
X30_2sq
03010054
03010054
Screw tightly
5 Setting up and Commissioning User Manual SIPLACE CA-Series
5.5 Setting Up the Placement Machine From software version SC.708.0 Edition 12/2014 EN -DRAFT
300
5.5.8.3 Fitting the Axis Unit
Carefully lift the axis unit onto the rail in the extension kit.
Make sure that you do not squash any cables.
Push the axis unit into the extension kit as far as the stop.
Secure the axis unit with the fillister head screw.
Insert the cover.
Fasten the ground cable to the door (item 2 in fig. 5.5 - 8, page 292), as shown in fig. 5.5 - 10
on page 296
.
Lock the doors.
5.5.8.4 Fitting the Side Plates
Fasten the ground cable to each side plate (item 6 in fig. 5.5 - 8, page 292), as shown in fig.
5.5 - 10
page 296.
Fix the side plate to the machine frame with 6 fillister head screws.
5
5
PLEASE NOTE
Input conveyor dismantled
Continue with section 5.5.9 " Fitting the Input Conveyor" on page 301.
PLEASE NOTE
Input conveyor fitted
Continue with assembly work, as described in section 5.5.14 "Fitting the Main Fault
Indicators" on page 321.
User Manual SIPLACE CA-Series 5 Setting up and Commissioning
From software version SC.708.0 Edition 12/2014 EN -DRAFT 5.5 Setting Up the Placement Machine
301
5.5.9 Fitting the Input Conveyor
5.5.9.1 Tools
Allen keys, DIN 911, set
Phillips screwdriver, size 1
5.5.9.2 Assembly
5
Fig. 5.5 - 13 Input conveyor - dual conveyor
(1) Side panel, input conveyor
(2) Side panel, processing conveyor 1
(3) Cable cover 20 x 200
(4) Countersunk screw, ISO 7046, M3x6, 2x per cable cover
(5) Cable cover 20 x 310
(6) Fillister head screw DIN 912, M3x5, 1x per cable cover
(7) Fillister head screw DIN 912, M6x16, and washer, 4 per panel
(8) Hexagonal shaft guidance
(9) Hexagonal shaft (single conveyor: one, dual conveyor: two)
(10) Drive unit