7 Component and Die Handling User Manual SIPLACE CA-Series 7.1 X Feeder Modules for SIPLACE X-Series From software version SC.708.0 Edition 12/2014 EN -DRAFT 402 7.1.2 T echnical Data for the SI PLACE X-Series Feeder Mod…

100%1 / 518
User Manual SIPLACE CA-Series 7 Component and Die Handling
From software version SC.708.0 Edition 12/2014 EN -DRAFT 7.1 X Feeder Modules for SIPLACE X-Series
401
7
Fig. 7.1 - 2 Tape feeder module 8 mm X - back view
(1) Entry to the tape guide channel with tape spring
(2) Flap on cover foil container
(3) Integrated blade for cutting off the cover foil
(4) Removal handle, engaged
(5) Operator panel
(6) Drive motor for the cover foil packing device
(7) Drive motors for the tape conveyor
(8) Rotary valve for removing components
(9) Front slider guide
(10) Back slider guide
(11) Graphical representation of the pick-up position in relation to the component size
7 Component and Die Handling User Manual SIPLACE CA-Series
7.1 X Feeder Modules for SIPLACE X-Series From software version SC.708.0 Edition 12/2014 EN -DRAFT
402
7.1.2 Technical Data for the SIPLACE X-Series Feeder Modules
The following pages contain pictures of the X-Series feeder modules and the technical data.
7.1.2.1 Tape Feeder Module 4 mm X
7
Fig. 7.1 - 3 Tape Feeder Module 4 mm X
7
Tape Feeder Module 4 mm X Item no. 00141268-xx
Width 10.8 mm
Feeder module locations filled 1
Conveyor increment 1 mm
Changeover time for the component tape < 45 s
Changeover time for the preset feeder module
on the machine
8 s
User Manual SIPLACE CA-Series 7 Component and Die Handling
From software version SC.708.0 Edition 12/2014 EN -DRAFT 7.1 X Feeder Modules for SIPLACE X-Series
403
7.1.2.2 SIPLACE Smart Feeder 2x8 mm X
7
Fig. 7.1 - 4 SIPLACE Smart Feeder 2x8 mm X
7
SIPLACE Smart Feeder 2x8 mm X Item no. 00141269-xx
SIPLACE Smart Feeder 2x8 mm X with splice sensor Item no. 00141289-xx
Width 22.6 mm
Feeder module locations filled 2
Conveyor increment 1 mm / 2 mm / 4 mm / 8 mm
Changeover time for one tape < 45 s
Changeover time for the preset feeder module
on the machine
8 s