00197498-03_UM_SiplaceCA-Serie_EN.pdf - 第440页
7 Component and Die Handling User Manual SIPLACE CA-Series 7.5 Docking Station for the SIPLACE X-Series Component Tr olley From software version SC.708.0 Edition 12/2014 EN -DRAFT 440 7 Fig. 7.5 - 2 Docking station - dim…

User Manual SIPLACE CA-Series 7 Component and Die Handling
From software version SC.708.0 Edition 12/2014 EN -DRAFT 7.5 Docking Station for the SIPLACE X-Series Component Trolley
439
The main tasks performed by the docking station are as follows:
– Supply of energy to the component trolley and X feeder modules
– Supply of compressed air to the component trolley and X feeder modules
– Provision of an infrastructure for communication between the pre-setup location PC and
the feeder modules
7.5.2 Functions
With the help of the docking station, the operator can perform function tests to the X feeder mod-
ules outside the production environment and can check the setup. There are two rows, each with
four docking stations, connected via the CAN bus of the pre-setup PC. Each docking station has
its own power and compressed air connection.
The component trolley COT insert (item 2 in fig. 7.5 - 1
) for the docking station can be adjusted to
the required PCB conveyor height. To perform the pre-setup tasks, the component trolley is
pushed into the docking station (item 1 in fig. 7.5 - 1
). The component trolley slides along the COT
insert rails, with the roller bearings on the side of the component trolley, up to the energy and data
interface connection. The changeover table and feeder EDIF are aligned in the optimum position
to the EDIF (item 4 in fig. 7.5 - 1
, page ) of the COT insert and fixed in this position with the two
clamping levers.
7.5.3 Technical Data
7
Dimensions
Length x width 950 mm x 930 mm
Height 864 mm for 900 mm PCB conveyor height
894 mm for 930 mm PCB conveyor height
914 mm for 950 mm PCB conveyor height
Weight 120 kg
Compressed air pressure val-
ues
p
min
p
max
0.5 MPa (5.0 bar)
1.0 MPa (10.0 bar)
Compressed air connection Connection plug KS 2-M5-A
Compressed air consumption 50 Nl/min
*a
*)a Under normal atmospheric conditions at 20°C and 1013 hPa
Supply voltage 88 - 264 V~
Rated current 3.5 A (230 V~)
7 A (115 V~)
Nominal apparent power 0.8 kW
Fuse 2 x 8 A

7 Component and Die Handling User Manual SIPLACE CA-Series
7.5 Docking Station for the SIPLACE X-Series Component Trolley From software version SC.708.0 Edition 12/2014 EN -DRAFT
440
7
Fig. 7.5 - 2 Docking station - dimensions in millimeters, connection points
(1) Compressed air connection
(2) CAN bus connection
(3) Power supply connection

User Manual SIPLACE CA-Series 7 Component and Die Handling
From software version SC.708.0 Edition 12/2014 EN -DRAFT 7.5 Docking Station for the SIPLACE X-Series Component Trolley
441
7.5.4 Dimensions of Docking Station with Docked Component Trolley
7
Fig. 7.5 - 3 Docking station with docked component trolley - dimensions in millimeters
(1) Component trolley
(2) Docking station