00197498-03_UM_SiplaceCA-Serie_EN.pdf - 第361页

User Manual SIPLACE CA-Series 6 Working with the Machine From software version SC.708.0 Edition 12/20 14 EN -DRAFT 6.4 SWS Tasks 361 6 Fig. 6.4 - 4 Calibration standard for die ejector  Insert the needle un it into the …

100%1 / 518
6 Working with the Machine User Manual SIPLACE CA-Series
6.4 SWS Tasks From software version SC.708.0 Edition 12/2014 EN -DRAFT
360
6.4.5.1 Setting the Needle with the Calibration Standard 03080191-xx
Equipment
Needles as spare parts
Calibration standard for the die-ejector (03080191-xx)
With the help of the calibration standard for the die ejector all needles are adjusted into
a defined height and common level. 6
6
Fig. 6.4 - 3 Calibration standard for the die ejector - item number 03080191-xx
User Manual SIPLACE CA-Series 6 Working with the Machine
From software version SC.708.0 Edition 12/2014 EN -DRAFT 6.4 SWS Tasks
361
6
Fig. 6.4 - 4 Calibration standard for die ejector
Insert the needle unit into the calibration standard for the die-ejector (1). During that the cen-
tering bolt (5) is inserted into the opening on the underside of the ejection unit.
Draw back the ejection unit until it lies fully in the prism. After releasing the crank at the ejec-
tion unit should now be pressed into a defined position against the limiter plate.
Move the alignment plate (2) to the needles not yet clamped.
Move the alignment plate as far as the stop against the bolts, so the needles are adjusted by
the plate in one defined height.
Carefully screw in the grub screws (3) (approx. 10Ncm).
Make sure that no needles have slipped. If they have, loosen the screws again and repeat
the process.
1
5
2
3
6 Working with the Machine User Manual SIPLACE CA-Series
6.4 SWS Tasks From software version SC.708.0 Edition 12/2014 EN -DRAFT
362
6.4.6 Checking and Configuring the Tools and Nozzles on the Flip Unit
Switch off the placement machine and the SWS properly.
Open the protective cover above the SWS.
6
Fig. 6.4 - 5 Flip unit with nozzles and reject bins
Legend
6
Check the state and type of the nozzles and tools on the flip unit. If necessary, replace them
with new ones or those appropriate for the product.
You can either use the standard nozzles of the SIPLACE placement machines or rubber tips
together with an appropriate adapter.
Proceed with checking the reject bins.
6.4.7 Checking the Reject Bin of the Flip Unit
Check and empty the reject bin on the flip unit (item 2 in fig. 6.4 - 5).
When replacing the reject bins make sure that the underlying surface is clean and that the bin
is seated correctly in its fixation. Otherwise they are not recognized by the sensors.
Close the protective cover above the SWS.
Switch the SWS and the placement machine on.
(1) Nozzle segment 1 (2) Nozzle segment 2
(3) Reject bin
2
3
3
1