7 Component and Die Handling User Manual SIPLACE CA-Series 7.2 SIPLACE X-Series Component Trolley From software version SC.708.0 Edition 12/2014 EN -DR AFT 434 7.2.7.2 Maximum T ape Reel Diameter in Relation to the PCB C…

100%1 / 518
User Manual SIPLACE CA-Series 7 Component and Die Handling
From software version SC.708.0 Edition 12/2014 EN -DRAFT 7.2 SIPLACE X-Series Component Trolley
433
7.2.7 SIPLACE X-Series Tape Container
7.2.7.1 Description
The tape container can hold reels up to 19" (483 mm) in diameter. The insertion of separating
plates is described in section 6.6.5
page 368.
7
Fig. 7.2 - 9 SIPLACE X-Series component trolley, with tape container
(1) Component trolley
(2) Position of spindles
(3) Waste tape container
(4) Tape container
(5) Separating plate
(6) Spindle (zoom)
7 Component and Die Handling User Manual SIPLACE CA-Series
7.2 SIPLACE X-Series Component Trolley From software version SC.708.0 Edition 12/2014 EN -DRAFT
434
7.2.7.2 Maximum Tape Reel Diameter in Relation to the PCB Conveyor Height
7
7
Without mount for the
additional tape reel
With mount for the additional tape reel
PCB conveyor
height
of the component
trolley
Tape reel diameter Tape reel diameter
without spindle with spindle
900 mm 19" 17" 15"
930 mm 19" 19" 17"
950 mm 19" 19" 19"
PLEASE NOTE
Using spindles
SIPLACE X-Series component trolleys do not generally need spindles.
Use spindles if the error message "Timeout" appears frequently on the X feeder mod-
ule.
User Manual SIPLACE CA-Series 7 Component and Die Handling
From software version SC.708.0 Edition 12/2014 EN -DRAFT 7.3 SIPLACE X-Series Used Tape Chute
435
7.3 SIPLACE X-Series Used Tape Chute
7
Fig. 7.3 - 1 Used tape chute for the COT insert of the SIPLACE X-Series
In accordance with the PCB conveyor height, the length of the used tape chute can be set so that
the tape cuttings are directly diverted into the waste tape container of the component trolley.
7
PLEASE NOTE
The used tape chute for the X-Series can only be installed on the COT insert for X-Series
(see fig. 6.14 - 3
, page 389) .