00197498-03_UM_SiplaceCA-Serie_EN.pdf - 第467页
User manual SIPLACE CA-Series 8 Station Extensions From software version SC.708.0 Edition 12/20 14 EN -DRAFT 8.1 Nozzle Changers 467 8.1.3.8 Nozzle Changer "Row 2" for the SIPLACE MultiS tar and S peedSt ar Ite…

8 Station Extensions User manual SIPLACE CA-Series
8.1 Nozzle Changers From software version SC.708.0 Edition 12/2014 EN -DRAFT
466
Press the magazine down evenly so that the snap fastener balls engage in all the snap fas-
teners at the same time.
8.1.3.7 Position detection
Each magazine of the nozzle changer has two fiducials: one for determining the position and one
for determining the angular position.
8
Fig. 8.1 - 16 Nozzle magazine - fiducials for determining the position and angular position
(1) Locking plate in the "magazine open" position
(2) Fiducial for determining the angular position
(3) Fiducial for determining the position

User manual SIPLACE CA-Series 8 Station Extensions
From software version SC.708.0 Edition 12/2014 EN -DRAFT 8.1 Nozzle Changers
467
8.1.3.8 Nozzle Changer "Row 2" for the SIPLACE MultiStar and SpeedStar
Item no. 00119742-xx Nozzle changer 2 for CPP, X-Series
The "row 2" nozzle changer can be installed at the following locations:
CA4 machine: Locations 1, 2, 3 and 4
The retrofit package contains the nozzle changer and an assembly kit.
8
Fig. 8.1 - 17 Assembly kit for the "row 2" nozzle changer
8
8

8 Station Extensions User manual SIPLACE CA-Series
8.1 Nozzle Changers From software version SC.708.0 Edition 12/2014 EN -DRAFT
468
8.1.4 Nozzle Changer for the SIPLACE TwinHead
[03005191-xx] Magazine for 2 nozzles
[03001807-xx] Magazine for 1 nozzle
This nozzle changer can accommodate up to 12 nozzle magazines. There are two different mag-
azine types available: standard magazines and magazines for special nozzles or grippers. The
magazines are seated on a common support. They are centered with two parallel pins and fixed
in place with two countersunk screws.
8
Fig. 8.1 - 18 Nozzle Changer for the SIPLACE TwinHead
8
WARNING
Risk of head crashes with mixed configurations!
There is a risk of head crashes with mixed configurations.
Only install the corresponding nozzle changer for each placement head, with the noz-
zle magazines for the respective placement head.