00197498-03_UM_SiplaceCA-Serie_EN.pdf - 第269页

User Manual SIPLACE CA-Series 5 Setting up and Commissioning From software version SC.708.0 Edition 12/20 14 EN -DRAFT 5.3 Delivery Configuration and Transpo rtation of SWS 269 5.3.3.3 Fork Lif t Attachment Point s on th…

100%1 / 518
5 Setting up and Commissioning User Manual SIPLACE CA-Series
5.3 Delivery Configuration and Transportation of SWS From software version SC.708.0 Edition 12/2014 EN -DRAFT
268
5.3.3 Transporting the SWS Without a Crate or Pallet
5.3.3.1 Safety instructions
5
5
5
5.3.3.2 Means of Transport
Use a fork-lift truck or suitable hand lift with the following specification to carry the machine:
5
5
WARNING
Observe the applicable accident prevention regulations!
The applicable accident prevention regulations concerning the transportation of
heavy goods must be followed.
WARNING
DANGER OF CRUSHING!
Risk of crushing feet when transporting the machine.
Wear special protective shoes.
WARNING
Damage to the machine!
Risk of damaging the machine if it is transported without crate or pallet.
Read this section through completely before transporting the machine.
Fork length Min. 1600 mm
Lifting power Min. 1500 kg
Outer fork width Min. 450 mm
Max. 520 mm
PLEASE NOTE
Hand Lift Specifications
The necessary width of the fork lift presents a critical measure.
Make sure that the hand lift used fulfills the specified requirements.
User Manual SIPLACE CA-Series 5 Setting up and Commissioning
From software version SC.708.0 Edition 12/2014 EN -DRAFT 5.3 Delivery Configuration and Transportation of SWS
269
5.3.3.3 Fork Lift Attachment Points on the SWS
5
. 5
Fig. 5.3 - 2 Attachment points for fork-lift or hand lift on SWS
5.3.3.4 Points to be Observed While Transporting the SWS
5
WARNING
Only lift the SWS by its metal frame.
WARNING
Center of Gravity for SWS
Keep an eye on the SWS center of gravity (see section 3.4.8), particularly when mov-
ing it sideways.
5 Setting up and Commissioning User Manual SIPLACE CA-Series
5.4 Infrastructure at the Installation Location From software version SC.708.0 Edition 12/2014 EN -DRAFT
270
5.4 Infrastructure at the Installation Location
5.4.1 Recommendations for Foundation Quality
The foundation on which the placement machine or SWS is installed should be firm and level, as
dynamic forces can cause vibrations when the placement machine is operated. The degree of vi-
bration depends on the construction of the foundation. The following are suitable provided that the
floor loading parameters, etc., are not exceeded:
Reinforced concrete ceiling constructions, e.g. ceilings in production halls
Reinforced concrete floor slabs, e.g. concrete floors in production halls without a basement
Rooms with double floors, provided that a stable foundation is included in the space between
them. The same setup conditions apply to this intermediate foundation, which can be made
from steel girders or concrete.
5.4.1.1 Machine Weight and Floor Loading
The machine weight and floor loading values can be found in section 3.4.4, page 135.
5
5.4.1.2 Vibration Limits
The placement machine is not susceptible to floor vibrations but the following vibration limits
should still be observed.
5
5
Parameters Values
Third-octave spectral value of the vibration speed 5 - 100 Hz
v < 250 µm/s
v
max
value on the time curve v
max
< 1.5 mm/s